Hotpoint EC6005 manual Electrical connection, For example line 1 in the table

Models: EC6005

1 16
Download 16 pages 48.21 Kb
Page 6
Image 6
Electrical connection

Electrical connection

The electrical safety of this appliance can only be guaranteed if the latter is correctly and efficiently earthed, in compliance with regulations on electrical safety. Always ensure that this vital safety measure has been taken. If you have any doubts, call in a qualified technician to check the electrical system thoroughly.

The manufacturer denies all responsibility for dam- age resulting from a system which has not been earthed correctly.

Before powering the appliance, check whether the technical characteristics featured on the appliance data plate correspond with those of the mains electrical sys- tem.

Check that the current load of the mains supply and of the power sockets is suitable for the maximum power of the appliance, indicated on the appliance data plate. If in doubt, contact a qualified professional.

Disconnect the appliance from the electricity supply before all operations.

You may connect your hob to the electrical system in two different ways:

by means of ajunction box: if the appliance is connected permanently to the mains, an omnipolar circuit breaker, accessible if necessary, with a mini- mum contact opening of 3 mm should be installed.

by means of a socket conforming to the regulations in force in the country where the appliance is fitted. It should be accessible whenever necessary; do not use adaptors, multiple plugs or extensions.

Important

After connecting the appliance to the flexible cable, tighten all the screws on the terminal board. Make sure jumpers are installed according to the type of mains system as indicated in the table.

For example: line 1 in the table

 

Electrical connections

Voltage

Fuses

 

Frequency

Sections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

 

 

 

 

 

230V-1+N~50 Hz

25 A*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.5 mm²

 

L

 

 

 

 

N

 

 

 

 

 

 

 

 

*Application of the simultaneity coefficient in accordance with IEC 60335-2-6 norm

In the event of an incorrect connection:

if your appliance does not work,

check the position of the wires in the terminal board,

check that all screws are tight,

check the positioning of the jumpers.

This appliance conforms with the following European Community Directives:

-73/23/EEC of 19/02/73 (Low Voltage) and subsequent amendments;

-89/336/EEC of 03/05/89 (Electromagnetic compatibility) and subsequent amendments;

-93/68/EEC of 22/07/93 and subsequent amendments;

Warning: If the hob is fitted above a built-in oven, the hob and the oven must be connected to the mains separately for safety reasons and to simplify operations when it is necessary to pull the oven out for some reason.

For example: line 1 in the tableManual background1 2

4

3

5

U-bolt Phase Neutral Earth connection support

6

Page 6
Image 6