![](/images/new-backgrounds/1064164/6416417x1.webp)
Burners and Nozzle Specifications
Table 1 |
|
|
|
|
| Liquid Gas |
|
| Natural Gas | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
Burner | Diameter | Thermal power | Nozzle |
| Flow* | Nozzle |
| Flow* | ||||
| (mm) | kW (p.c.s.*) | 1/100 | 1/100 |
| g/h | 1/100 |
| l/h | |||
|
| Nomin. |
| Ridot. | (mm) | (mm) | *** |
| ** | (mm) |
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Fast (R) | 100 | 3,00 |
| 0,70 | 41 | 86 | 218 |
| 214 | 116 |
| 286 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Semi Fast (S) | 75 | 1,90 |
| 0,40 | 30 | 70 | 138 |
| 136 | 106 |
| 181 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Auxiliary (A) | 55 | 1,00 |
| 0,40 | 30 | 50 | 73 |
| 71 | 79 |
| 95 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Supply | Nominal (mbar) |
|
|
| 37 |
| 20 | |||||
Minimum (mbar) |
|
| 20 |
| 25 |
| 17 | |||||
Pressures |
|
|
|
| ||||||||
Maximum (mbar) |
|
| 35 |
| 45 |
| 25 | |||||
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
**At 15°C and 1013
**Propane P.C.S. = 50.37 MJ/kg.
***Butane P.C.S. = 49.47 MJ/kg. Natural P.C.S. = 37.78 MJ/m3
Gas Section:Class | II2H3+ |
Rated Power kW (1) | 7,8 |
|
(1)Values in g/h refer to capacities with liquid gas (Butane, Propane).
It is the law that all gas appliances are installed by competent persons in accordance with the currect edition of the Gas Safety (Installation and Use) Regulations. It is in your interest and that of safety to ensure compliance with the law.
In the UK, CORGI registered installers work to a safe standard of practice.
The hob must be installed in accordance with BS6172:
Failure to install the hob correctly could invalidate the warranty liability claims and could lead to prosecution.
9