14

3.2 INSTALLATION
Pick a location which will allow the conditioned air to blow
into the area you want. Good installation with special
attention to the proper position of the unit will lessen the
chance that service will be needed.

ITEMS IN INSTALLATION HARDWARE

You may not need all parts in the kit. Discard unused parts
HOW TO INSTALL
Before installing the unit, identify the existing wall sleeve
from the list below.
NOTE: All wall sleeves used to mount the new Air
Conditioner must be in sound structural condition and have a
rear grille that securely attaches to sleeve, or rear flange that
serves as a stop for the Air Conditioner.
Remove old air conditioner from existing wall sleeve.
Clean the interior of an existing sleeve.
(Do not disturb seals.)
Wall sleeve must be securely fastened in wall before
installing the air conditioner. Use the nails or screws
through sleeve into wall, if needed. Repaint sleeve if
needed.
Prepare the wall sleeve for installation of the unit. If you
plan to use your existing wall sleeve, and it is not
FRIEDRICH, use procedure B or C below.
Install new unit into wall sleeve.
CAUTION: When installation is completed, replacement unit
MUST have a rearward slope as shown. To achieve 1/4"
slope, remove the backing from the 11-13/16" shim strips and
attach them as shown below in Fig. 19. Place the higher
portion of shim to the front of the rib on base of wall sleeve.
1
2
3
4
5
6
1/4"
Wall Sleeve
FRONT
UNIT
SHIM PLACEMENT UNIT INSTALLATION
1" high 3/4" High
Shim
6" 6"
FIG. 19

Installing the FRIEDRICH USC sleeve ensures

optional performances of the unit.

If you decide to keep the existing wall sleeve, you have

to redirect the louvers at the back of the wall sleeve.

Refer to FIG. 23 on p15. The use of pliers is

recommended. If you DO NOT redirect, you run the risk

of poor performance or premature product failure. This

is not covered under the terms of the FRIEDRICH

warranty.

Procedure Brand
Depth(inches)
A(page 16)
FRIEDRICH USC 16-23/32
White-Westinghouse
Frigidaire Carrier 16, 17-1/2
(52F series) or 22
General Electric 16-7/8
/Hotpoint
Whirlpool 17-1/8 or 23
Carrier (51S series) 18-5/8
Fedders/Emerson 16-3/4
Friedrich WSC or 19-3/4
Emerson/Fedders 15
B
(pages 17~18)
C
(pages 19)
ITEM (inches) Qty.
Plastic grille 263/4x 161/2 1
Vertical insulation strip 159/16x 13/8 x 13/81
Around Insulation Strips 671/8x 13/8x 25/32 1
5927/32x 1 3/8x 13/81
Horizontal Insulation Strip 237/32x 13/8x 13/16 1
Support Block 13/4x 13/8x 45/16 2
Baffle
14 x
41/2
x
1/81
Shim 1113/16 x 1 x 3/42
Trim Frame 2
Washer Screw 4
Nuts(Plastic) 4
Grille Rear 1
CAUTION
Wall Sleeve Dimensions (inches)
Brand Width Height Depth
White-Westinghouse
25-1/2 15-1/4 16, 17-1/2
Frigidaire or 22
Carrier (52F series)
General Electric 26 15-5/8 16-7/8
/Hotpoint
Whirlpool 25-7/8 16-1/2 17-1/8
or 23
Fedders/Emerson 27 16-3/4 16-3/4
Friedrich WSC or 19-3/4
FRIEDRICH USC 25-7/8 15-17/32 16-23/32
Emerson/Fedders 26-3/4 15-3/4 15
Carrier (51S Series) 25-3/4 16-7/8 18-5/8