Installer’s Instructions

Installer’s Instructions

GB

Installation

These Instructions are for the qualified technician, as a guide to installation, adjustment and maintenance, according to the Iaws and standards in force. These operations must aIways be carried out when the appliance has been disconnected from the eIectric system.

Positioning (Fig. 5)

The fixture is especially designed for fitting into a worktop as shown in the corresponding figure.

PIace the supplied sealing agent along the hob perimeter.

Do not install the hob over an oven; incase you do, make sure of the following:

-the oven is equipped with an appopriate cooling system

-there isno warm-air Ieakage from the oven to wards the hob

-suitabIe air-inIets are provided as shown in the figure.

Fig.6

~ 230V

N L

H05 V2V2–F 3x2.5

Electrical connection (Fig. 6)

Prior to carrying out the eIectrical connection, please ensure that:

-the plant characteristics are such as to follow what is indicated on the matrix plate placed atthe bottom of the working area;

-that the plant is fitted with an efficient earth connection, folIowing the standards and law provisions in force. The

earth connection is compulsory interrns of the law. Should there beno cable and/or plug on the equipment, use suitable absorption material for the working temperature as well, as indicated on the matrix plate. Under no circumstance must the cable reach a temperature above 50°C of the ambient temnerature.

If connecting directly to the mains power supply, fita multi- poie switch ofa suitable size for the rated capacity with a clearance distance which completely disconnects the power line under over voltage category III conditions, consistently with the rules of installation (the yellow/green earth wir must not be interrupted). The plug or omnipolar switch must be easily reached on the installed equipment.

N.B.: The manufacturers decline any responsibility in the event of non-compliance with what is described above and the accident prevention norms not being respected and followed.

To avoid all risk, if the power cable becomes damaged, it must only be replaced by the manufacturer, by an authorised service centre, or by a qualified electrician.