Electrical Connection
Electrical connection
The electrical connection to the mains must be made on the appliance. The power voltage and frequency are as indicated on the rating plate.
!THIS APPLIANCE MUST BE EARTHED.
Connecting the power supply cable
To open the terminal board:
•Using a screwdriver, press on the tabs situated on each side of the terminal board cover.
•Pull open the terminal board cover.
To connect the power supply cable, proceed as follows:
• | Unscrew the cable clamp screw and the contact |
| screws |
• | Fasten the wires beneath the screwheads using |
| the following colour scheme: Blue (N) Brown (L) |
|
|
Power cable supply connection to the electrical
mains:GB
We recommend you use a power supply cable which is long enough to allow you to take the oven out of its recess in the event of maintenance operations (only use HAR - H 05 - RRF quality cables fitted with a plug conforming to the regulations in force.
The plug must be accessible at all times.
Unplug the appliance before all operations, even when replacing the oven lamp.
Using the appliance without correct earthing is highly dangerous.
!After connecting the appliance to the flexible cable, tighten all the screws on the terminal board.
TABLE OF CHARACTERISTICS
| width 43.5 cm |
Dimensions | height 32 cm |
| depth 40 cm |
Volume | 56 l |
|
|
| width 43.5 cm |
Dimensions * | height 32 cm |
| depth 41.5 cm |
• Fasten the power supply cable in the |
corresponding cable clamp and close the cover. |
Volume *
Electrical connections
58 l
voltage: 220 - 240 V~ 50/60Hz maximum power absorbed 2800 W
Electrical Connection:
4 2 N L
Voltage Frequency: 230
Fuse Section: 16A Supply cable: 3x1.5mm2
ENERGY LABEL
(see data plate)
Directive 2002/40/EC on the label of electric ovens. Standard EN 50304
Energy consumption for Natural convection – heating mode: Traditional mode
Declared energy consumption for Forced convection Class – heating
mode: Baking
You can connect your oven to the system means of a terminal board. Refer to above information for the minimal cable sections and the calibration of the protective elements according to the connection.
If the appliance is installed with a junction box, an omnipolar circuit breaker - with a minimum contact opening of 3mm - should be installed between the appliance and the mains.
This appliance conforms to the following European Economic Community directives: 2006/95/EEC dated 12/12/06 (Low Voltage) and subsequent amendments – 2004/108/EEC dated 15/12/04 (Electromagnetic Compatibility) and subsequent amendments - 93/68/EEC dated 22/07/93 and subsequent amendments. 2002/96/EC and subsequent amendments.
1275/2008
* With glass panel fitted to the inside of the door
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
3