Hotpoint SX 53 X, SBS 51 X Electrical Connection, 4 2 N L, Electrical connection

Models: SBS 51 X SX 53 X

1 16
Download 16 pages 33.99 Kb
Page 4
Image 4
Electrical Connection

Electrical Connection

Electrical connection

GB

The electrical connection to the mains must be made on the appliance. The power voltage and frequency are as indicated on the rating plate.

!THIS APPLIANCE MUST BE EARTHED.

Connecting the power supply cable

To open the terminal board:

Using a screwdriver, press on the tabs situated on each side of the terminal board cover.

Pull open the terminal board cover.

To connect the power supply cable, proceed as follows:

Unscrew the cable clamp screw and the contact screws L-N-.

Fasten the wires beneath the screwheads using the following colour scheme: Blue (N) Brown (L) Yellow-Green

Fasten the power supply cable in the corresponding cable clamp and close the cover.

Electrical Connection:

Voltage Frequency: 230

V-1+N 50Hz

Fuse Section: 16A

Supply cable: 3x1.5mm2

4 2 N L

You can connect your oven to the system means of a terminal board. Refer to above information for the minimal cable sections and the calibration of the protective elements according to the connection.

If the appliance is installed with a junction box, an omnipolar circuit breaker - with a minimum contact opening of 3mm - should be installed between the appliance and the mains.

Power cable supply connection to the electrical mains:

We recommend you use a power supply cable which is long enough to allow you to take the oven out of its recess in the event of maintenance operations (only use HAR - H 05 - RRF quality cables fitted with a plug conforming to the regulations in force.

The plug must be accessible at all times.

Unplug the appliance before all operations, even when replacing the oven lamp.

Using the appliance without correct earthing is highly dangerous.

!After connecting the appliance to the flexible cable, tighten all the screws on the terminal board.

DATA PLATE

Dimensions

width cm 43.5

height cm 32

 

depth cm 41.5

Volume

lt. 58

Electrical

voltage: 230-240V ~ 50/60 Hz

(see data plate)

connections

maximum power absorbed

 

2250-2400W

 

Directive 2002/40/EC on the label

 

of electric ovens.

 

Standard EN 50304

 

Energy consumption for Natural

ENERGY LABEL

convection – heating mode:

Convection mode

 

 

Declared energy consumption for

 

Forced convection Class – heating

 

mode: Multi-cooking

 

This appliance conforms to the

 

following European Economic

 

Community directives:

 

- 2006/95/EEC of 12/12/06 (Low

 

Voltage) and subsequent

 

amendments;

 

-2004/108/EEC of 15/12/04

 

(Electromagnetic Compatibility) and

 

subsequent amendments;

 

- 93/68/EEC of 22/07/93 and

 

subsequent amendments.

 

- 2002/96/EC and subsequent

 

amendments.

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

4

Page 4
Image 4
Hotpoint SX 53 X, SBS 51 X operating instructions Electrical Connection, 4 2 N L, Electrical connection