Hotpoint SY56 Installation, hazard. see Precautions and tips, Fitting the appliance, Ventilation

Models: KSO53CX SH51X SH53X SH53CKX SHS53CX SH53K SHS53X SH53CX SY10X SY51

1 16
Download 16 pages 45.22 Kb
Page 2
Image 2
Installation

Installation

 

! Before you operate yuor new Hotpoint Single Oven,

GB

please read these instructions fully. They contain

 

important information for safe use, for installation and

 

 

for care of the appliance.

 

! Please keep these operating instructions for future

 

reference. Pass them on to possible new owners of

 

the appliance.

 

! Keep packaging material out of the reach of

 

children. It can become a choking or suffocation

 

hazard. see Precautions and tips).

Positioning

!The appliance must be installed by a qualified person in compliance with the instructions provided. Incorrect installation may cause harm to persons, animals or may damage property.

Fitting the appliance

Use the appropriate cabinet to ensure that the appliance functions properly.

The panels adjacent to the oven must be made of heat-resistant material.

Cabinets with a veneer exterior must be assembled with glues which can withstand temperatures of up to 100°C.

To install the oven under the counter (see diagram) and in a kitchen unit, the cabinet must have the following dimensions:

Ventilation

To ensure good ventilation, the back panel of the cabinet must be removed. It is advisable to install the oven so that it rests on two strips of wood, or on a completely flat surface with an opening of at least 45 x 560 mm (see diagrams).

.

45

mm

.

mm

 

560

 

 

 

Centring and fastening

Position the 4 tabs on the side of the oven according to the 4 holes of the outer frame. Adjust the tabs according to the thickness of the cabinet side panel, as shown below:

thickness of 20 mm: take off the removable part of the tab (see diagram)

thickness of 18 mm: use the first groove, which has already been set in the factory (see diagram)

595 mm.

23 mm.

567 mm.

 

5 mm.

 

.

.min

mm

 

547

.

 

mm

45

 

560

mm.

 

575-585 mm.

thickness of 16 mm: use the second groove (see diagram)

595

mm.

.

 

mm

 

 

545

 

.

 

 

mm

 

24

 

!The appliance must not come into contact with electrical parts once it has been installed.

The consumption indications on the data plate have been calculated for this type of installation.

Secure the appliance to the cabinet by opening the oven door and putting 4 screws into the 4 holes of the outer frame.

!All parts which ensure the safe operation of the appliance must not be removable without the aid of a tool.

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24