Electrical Connection
Electrical connection
The electrical connection to the mains must be made on the appliance. The power voltage and frequency are as indicated on the rating plate.
!THIS APPLIANCE MUST BE EARTHED.
Fitting the power supply cable
Power cable supply connection to the electrical mains:
GB
We recommend you use a power supply cable which is long enough to allow you to take the oven out of its recess in the event of maintenance operations (only use HAR - H 05 - RRF quality cables fitted with a plug conforming to the regulations in force.
The plug must be accessible at all times.
L |
N
1.Open the terminal board by inserting a screwdriver into the side tabs of the cover. Use the screwdriver as a lever by pushing it down to open the cover (see diagram).
2.Install the power supply cable by loosening the cable clamp screw and the three wire contact screws
Unplug the appliance before all operations, even when replacing the oven lamp.
Using the appliance without correct earthing is highly dangerous.
!After connecting the appliance to the flexible cable, tighten all the screws on the terminal board.
DATA PLATE
Dimensions | width cm 43.5 |
height cm 32 | |
| depth cm 41.5 |
Volume | lt. 58 |
|
|
Electrical | voltage: |
|
marked (see diagram).
3.Secure the cable by fastening the clamp screw.
4.Close the cover of the terminal board.
Electrical Connection:
Voltage Frequency: 230
Fuse Section: 16A
Supply cable: 3x1.5mm2
You can connect your oven to the system means of a terminal board. Refer to above information for the minimal cable sections and the calibration of the protective elements according to the connection.
If the appliance is installed with a junction box, an omnipolar circuit breaker - with a minimum contact opening of 3mm - should be installed between the appliance and the mains.
connections | 50Hz (see data plate) | |
maximum power absorbed | ||
| ||
| Directive 2002/40/EC on the label | |
| of electric ovens. | |
| Standard EN 50304 | |
| Energy consumption for Natural | |
ENERGY LABEL | convection – heating mode: a | |
Convection mode | ||
| ||
| Declared energy consumption for | |
| Forced convection Class – heating | |
| mode: b | |
| This appliance conforms to the | |
| following European Economic | |
| Community directives: | |
| - 2006/95/EEC of 12/12/06 (Low | |
| Voltage) and subsequent | |
| amendments; | |
| ||
| (Electromagnetic Compatibility) and | |
| subsequent amendments; | |
| - 93/68/EEC of 22/07/93 and | |
| subsequent amendments. | |
| - 2002/96/EC and subsequent | |
| amendments. |