ProCurve Switch 5400zl/3500yl Series

Specifications

 

ProCurve Switch 5412zl Intelligent Edge (J8698A)

ProCurve Switch 5412zl-96G Intelligent Edge (J8700A)

Included accessories

N/A

4

ProCurve Switch zl 24-Port 10/100/1000 PoE Modules (J8702A)

 

 

2

ProCurve Switch zl 875W Power Supplies (J8712A)

 

 

 

 

Ports

12 open module slots

 

1 RS-232C DB-9 console port

 

Supports a maximum of 288 auto-sensing 10/100/1000 ports or

 

48 10-GbE ports or 288 mini-GBICs, or a combination

8 open module slots

96 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T) with PoE Media type: IEEE Auto-MDIX

Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only

1 RS-232C DB-9 console port

Supports a maximum of 288 auto-sensing 10/100/1000 ports with PoE or 32 10-GbE ports or 192 mini-GBICs, or a combination

Power supplies

4 open power-supply slots

Includes 2 x J8712A

 

 

2 open power-supply slots

 

 

 

Physical characteristics

 

 

Dimensions (D x W x H)

45.09 x 44.45 x 30.73 cm (17.75 x 17.5 x 12.1 in.) (7U height)

45.09 x 44.45 x 30.73 cm (17.75 x 17.5 x 12.1 in.) (7U height)

Weight

15.85 kg (34.94 lb.)

26.31 kg (58 lb.)

 

 

 

Memory and processor

 

 

Gigabit module

ARM9 @ 200

MHz; packet buffer size: 144 Mb QDR SDRAM

10G module

ARM9 @ 200

MHz; packet buffer size: 36 Mb QDR SDRAM

Management module

Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact

 

flash, 256 MB DDR SDRAM

ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM

ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM

Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM

Mounting

Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only

 

 

Performance

Latency

1000 Mb

10Gbps Throughput Routing/Switching capacity Switch fabric speed Routing table size

<3.7 µs (FIFO 64-byte packets) <2.1 µs (FIFO 64-byte packets) Up to 428 million pps

576Gbps

692Gbps 10,000 entries

<3.7 µs (FIFO 64-byte packets) <2.1 µs (FIFO 64-byte packets) Up to 428 million pps

576Gbps

692Gbps 10,000 entries

Environment

Operating temperature

Operating relative humidity Non-operating/Storage temperature Non-operating/Storage

relative humidity Altitude Acoustic

0°C to 55°C (32°F to 131°F); 0°C to 40°C with J8705A, J8706A, or J8707A modules installed

15% to 95% @ 55°C (131°F), non-condensing –40°C to 70°C (–40°F to 158°F)

15% to 95% @ 65°C (149°F), non-condensing

Up to 4.6 km (15,000 ft.)

Power: 64 dB; pressure: 57.5 dB

ISO 7779, ISO 9296

0°C to 55°C (32°F to 131°F); 0°C to 40°C with J8705A, J8706A, or J8707A modules installed

15% to 95% @ 55°C (131°F), non-condensing –40°C to 70°C (–40°F to 158°F)

15% to 95% @ 65°C (149°F), non-condensing

Up to 4.6 km. (15,000 ft)

Power: 64 dB; pressure: 57.5 dB

ISO 7779, ISO 9296

Electrical characteristics

Description

Maximum heat dissipation

Voltage

Frequency

Notes

Chassis ships without power supplies. Four power-supply slots available; two different power supplies available. See power-supply products for additional specifications.

5,169 kJ/hr (4,900 BTU/hr) (max non-PoE)

7,807 kJ/hr (7,400 BTU/hr) (max using PoE) 100–127 VAC/200–240 VAC

50/60 Hz

Power supplies must be ordered separately. A combination of two power supplies either J8712A or J8713A is required to power the J8698A chassis.

Heat dissipation does not include heat dissipated by the PoE powered devices themselves.

Two J8712A installed. Two open power-supply slots available; two different power supplies available. See power-supply products for additional specifications.

5,169 kJ/hr (4,900 BTU/hr) (max non-PoE)

7,807 kJ/hr (7,400 BTU/hr) (max using PoE) 100–127 VAC/200–240 VAC

50/60 Hz

Heat dissipation does not include heat dissipated by the PoE powered devices themselves.

Safety

CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950

 

 

 

 

Emissions

FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A

 

 

 

 

Immunity

 

 

EN

EN 55024, CISPR 24

EN 55024, CISPR 24

ESD

IEC 61000-4-2; 4 kV CD, 8 kV AD

IEC 61000-4-2; 4 kV CD, 8 kV AD

Radiated

IEC 61000-4-3; 3 V/m

IEC 61000-4-3; 3 V/m

EFT/Burst

IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)

IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)

Surge

IEC 61000-4-5; 1 kV/2 kV AC

IEC 61000-4-5; 1 kV/2 kV AC

Conducted

IEC 61000-4-6; 3 V

IEC 61000-4-6; 3 V

Power frequency magnetic field

IEC 61000-4-8; 1 A/m, 50 or 60 Hz

IEC 61000-4-8; 1 A/m, 50 or 60 Hz

Voltage dips and interruptions

IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction,

IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction,

 

25 periods

25 periods

Harmonics

EN 61000-3-2, IEC 61000-3-2

EN 61000-3-2, IEC 61000-3-2

Flicker

EN 61000-3-3, IEC 61000-3-3

EN 61000-3-3, IEC 61000-3-3

 

 

 

9