HP 4445-95 manual Vertical Sealless Sprayer/Washer Pumps, Maintenance

Models: 4445-95

1 5
Download 5 pages 17.9 Kb
Page 2
Image 2

Specifications Information and Repair Parts Manual

4445-95, 4446-95, 5570-95, 5571-95 and 5572-95

Vertical Sealless Sprayer/Washer Pumps

Maintenance

WARNING Make certain that unit is disconnected from power source before attempting to service or remove any component.

IMPELLER/MOTOR REPLACEMENT Refer to Figure 2, and 3.

1.Remove unit from the tank or reservoir.

2.Remove fasteners (Ref No. 8) and washers if present (Ref. No. 7) that connect the volute base (Ref. No. 17) to the volute cover (Ref. No. 10).

3.Remove volute base, and gasket (Ref. No. 16).

4.Place an allen wrench through the slot in the top of the column and into one of the socket head screws of the shaft coupling. Rotate impeller counterclockwise until allen wrench stops against side of slot. Remove nut (Ref. No. 15) and then impeller from drive shaft by rotating each counterclockwise.

IMPORTANT: Care should be taken to insure that same number of shim washers (Ref. No. 9), if present, is replaced behind impeller as were removed. These shim washers are located directly behind the impeller. Shim washers may or may not be present depending on assembly clearances.

5.Remove allen wrench from slot and then remove the four fasteners (Ref. No. 5) and washers or nuts (Ref. No. 4) that connect the motor (Ref. No. 1) to the column (Ref. No. 3).

6.Remove the motor with shaft (Ref. No. 13) and coupling (Ref. No. 2) from the column.

7.Measure the distance from the shaft coupling to the motor mounting surface. Record this measurement.

8.Loosen the two socket head screws, towards the motor, in the coupling. Slide the coupling/shaft from the motor.

9.To reassemble, slide the coupling/shaft on the motor. Replace drive key (Ref. No. 7) if removed (557? Series only). Position the coupling at the recorded distance from the motor

mounting surface. Securely tighten all four socket head screws in coupling.

10.Install motor/shaft assembly into column. Secure with four fasteners and washers.

11.Install impeller, shim washers if any, and nut. Position gasket on volute cover and install volute base with fasteners and washers. IMPORTANT: If impeller strikes volute spacer plate (Ref. No. 11) before bottoming on shaft shoulder, add two 0.020” shims behind impeller. Reinstall impeller.

12.Place pump in an upright position. Rotate shaft/impeller. Impeller cannot strike volute base or volute cover. If interference exists, install or remove shim washers behind the impeller. (See “SHIM ADJUSTMENT” section) If shimming does not correct interference, repositioning coupling/shaft/impeller assembly on motor shaft may be necessary.

VOLUTE SPACER PLATE

REPLACEMENT

The volute spacer plate is subject to wear only by abrasive liquids. If badly, worn this plate can be replaced easily.

1.Disassemble pump for access as described in IMPELLER/MOTOR REPLACEMENT, steps 1, 2, 3, and 4.

2.Remove two fasteners (Ref. No. 12) that connect the spacer plate to the volute cover.

3.Replace spacer plate.

4.Reassemble pump as described in steps 11 and 12.

SHIM ADJUSTMENT

1.When installing a replacement impeller (Ref. No. 14), motor (Ref. No. 1), volute spacer plate (Ref. No. 11) or volute base (Ref. No. 17), it may be necessary to adjust the number of shims (Ref. No. 9) to insure proper running clearance between impeller and volute base and spacer plate. Proceed as follows:

NOTE: A proper running clearance between impeller and volute base is 0.04” to 0.06”.

2

1.For impeller or motor replacement, add one 0.020” shim in addition to those removed, if any, originally.

2.Reassemble pump as described in steps 9, 10, 11, and 12 as described in

IMPELLER/MOTOR REPLACEMENT.

IMPORTANT: Insure that volute base is snugly in place and check shaft to make sure it is turning freely (rotate impeller by using impeller nut Ref. No. 15 and socket wrench). Tighten fasteners connecting motor to column and volute to base carefully. Rotate shaft while tightening so that motor bearings are not damaged in the event that too many shims were installed. If shaft seizes before fasteners are completely tight, disassemble pump and remove two shims and repeat assembly.

SHAFT SUPPORT REMOVAL Models 4445-95 and 4446-95 only.

These units are designed to operate without a bottom bearing. A shaft support (Ref. No. 20) is installed at the factory to protect the shaft from misalignment during shipping. If pump is noisy while operating, this support may be the cause. The shaft support can be removed to stop noisy operation. Shaft support should not be replaced.

1.Disassemble pump for access as described in IMPELLER/MOTOR REPLACEMENT, steps 1 through 6.

2.Press out shaft support. Do not remove support plate (Ref. No. 21).

3.Reassemble pump as described in steps 10, 11, and 12.

DEBRIS SCREEN CLEANING

Sprayer/Washer pumps are equipped with a debris screen (Ref. No. 18). This screen is supplied attached to volute base (Ref. No. 17) with 4 drive pins. This screen may be replaced if damaged.

If pump performance is reduced or severe vibration occurs during operation this screen may be clogged. Debris screen must be thoroughly cleaned to restore pump performance.

Page 2
Image 2
HP 4445-95 manual Vertical Sealless Sprayer/Washer Pumps, Maintenance