Installation and Operation

Econo-Mizer

INSTALLATION

Use Tables A & B to determine the proper size of fuse protection and the length and size of wiring required. Portable extension cords, if used, should be as short as possible to minimize voltage drop. Cords that are too long, or cords that are made of inadequate wire gauge, can cause the motor to fail.

 

 

TABLE A

(WIRE SIZE)

 

 

 

 

 

 

DISTANCE

 

 

MOTOR

25 FT

 

50 FT

 

100 FT

200 FT

 

 

 

 

 

 

982

(1/3 hp-115V)

#18 GA

#16 GA

#12 GA

#10 GA

986

(1 HP-230V)

#14 GA

#14 GA

#12 GA

#10 GA

996

(1-1/2 hp-220V)

#14 GA

#14 GA

#12 GA

#10 GA

 

 

TABLE B

(FUSE SIZE)

 

MOTOR

 

TYPE OF FUSE

 

NON-TIME DELAY

DUAL ELEMENT TIME DELAY

 

 

 

 

 

982

(1/3 hp-115V)

15

 

12

986

(1 HP-230V)

15

 

12

996

(1-1/2 hp-220V)

20

 

15

6