Before connecting the diagnostic station to a server blade:
1.Power down the server blade.
2.Remove the server blade from the server blade enclosure in the rack.
IMPORTANT: If the server blade is a ProLiant BL30p, install the server blade into a blade sleeve and connect the blade sleeve to a diagnostic station.
3.Place the server blade on a flat, level workspace.
4.Perform any upgrade or maintenance actions and replace the access panel.
Cabling the Diagnostic Station to a Server BladeThis document provides two methods for connecting the diagnostic station to a server blade:
•Direct cabling methodUse either method to be sure an option is correctly installed in the server blade. This method is recommended for installing an operating system on a server blade. The connection can be made in one of two ways:
—With a client
CAUTION: Disconnect the local I/O cable when not in use. The port and connector do not provide a permanent connection. Rear iLO connector performance degrades when the local I/O cable is in use, even when the iLO connector on the cable is not in use.
HP ProLiant BL | 15 |