QuickSpecs
Family Information
HP StorageWorks P2000 G3 Modular Smart Array Systems
| P2000 G3 FC | P2000 G3 SAS | P2000 G3 10GbE | P2000 G3 iSCSI |
|
|
| iSCSI | (1GbE) |
|
|
|
|
|
Capacity | LFF: 7.2 TB SAS | LFF: 7.2 TB SAS | LFF: 7.2 TB SAS | LFF: 7.2 TB SAS |
Minimum / with | or 24 TB SAS MDL or | or 24 TB SAS MDL or | or 24 TB SAS MDL or | or 24 TB SAS MDL or |
maximum additional | SATA | SATA | SATA | SATA |
drive enclosures | w/ 7 LFF enclosures: | w/ 7 LFF enclosures: | w/ 7 LFF enclosures: | w/ 7 LFF enclosures: |
| 57.6 TB SAS | 57.6 TB SAS | 57.6 TB SAS | 57.6 TB SAS |
| or 192 TB SAS MDL or | or 192 TB SAS MDL or | or 192 TB SAS MDL or | or 192 TB SAS MDL or |
| SATA | SATA | SATA | SATA |
| SFF: 7.2 TB SAS | SFF: 7.2 TB SAS | SFF: 7.2 TB SAS | SFF: 7.2 TB SAS |
| or 12 TB SATA | or 12 TB SATA | or 12 TB SATA | or 12 TB SATA |
| w/ 5 D2700 JBODs: | w/ 5 D2700 JBODs: | w/ 5 D2700 JBODs: | w/ 5 D2700 JBODs: |
| 44.7 TB SAS | 44.7 TB SAS | 44.7 TB SAS | 44.7 TB SAS |
| or 74.5 TB SATA | or 74.5 TB SATA | or 74.5 TB SATA | or 74.5 TB SATA |
|
|
|
|
|
Controller Cache | 2 GB per controller | 2 GB per controller | 2 GB per controller | 2 GB per controller |
Total LUNs | 512 | 512 | 512 | 512 |
Host connect | Two 8 Gb | Four 6 Gb (x4) | Two 10 GbE iSCSI | Four 1 Gb |
P2000 & MSA2000 have | Fibre Channel ports or | SAS ports | ports per controller | iSCSI ports |
1 or 2 controllers, EVA | Two 8Gb FC and two | per controller |
| per controller |
has 2 controllers | 1GbE iSCSI ports |
|
|
|
standard | per controller |
|
|
|
|
|
|
|
|
Maximum Drives | 96 LFF/149 SFF | 96 LFF/149 SFF | 96 LFF/149 SFF | 96 LFF/149 SFF |
w/ expansion |
|
|
|
|
|
|
|
|
|
Maximum host | 64 | 8 single path | 64 | 64 |
supported |
| 4 dual path |
|
|
(dual controller) |
|
|
|
|
|
|
|
|
|
Optional software: | Snapshot, 64 standard | Snapshot, 64 standard | Snapshot, 64 standard | Snapshot, 64 standard |
Snapshot, clone, | (max 512) | (max 512) | (max 512) | (max 512) |
Remote Snap | Clone (standard) | Clone (standard) | Clone (standard) | Clone (standard) |
| Remote Snap (optional) |
|
|
|
|
|
|
|
|
Use for Storage | Primary Storage | Primary Storage | Primary Storage | Primary Storage |
| with SAS drives. | with SAS drives. | with SAS drives. | with SAS drives. |
| Secondary with SATA | Secondary with SATA | Secondary with SATA | Secondary with SATA |
|
|
|
|
|
NOTE: maximum available storage capacity depends on the RAID level being implemented
Product Technology
8Gb Fibre Channel Two host ports per FC controller shipped with SFPs. The P2000 G3 FC controller can run in either
controllerpoint-to-point or FCAL (loop). The default is FCAL which is used in Direct Connect, particularly with two controllers. The PtP (fabric) mode is used with almost all switches.
Combo controller | This ingenious |
with FC and iSCSI | while designating the two 1 GbE iSCSI ports to enable remote replication over iSCSI protocol and |
ports | perform as an iSCSI target. This allows economical sharing of the storage resource (the P2000 G3 |
| array) with one department needing the performance afforded by the 8 Gb FC ports while |
| simultaneously supporting another department with lesser performance needs and a budget only |
| allowing a 1GbE iSCSI network. |
6Gb SAS controller | Four 4x host ports per 6Gb SAS controller. |
10GbE iSCSI | Two 10GbE ports per G3 10GbE iSCSI controller. Ports are ready for the choice of SFP (none |
controller | included) |
| Supports the ProCurve and ISS versions of the following 10GbE parts for use in the controllers: |
| HP 10Gb Cables |
| HP SFP+ 10GbE Copper Cable |
| HP ProCurve |
| HP SFP+ Transceivers |
HP BladeSystem 10Gb SR SFP+ and HP BladeSystem 10Gb LRM SFP+
HP ProCurve
Transceiver
No SFP+ LR Transceiver support
1 Gb iSCSI controller Four 1 Gb Ethernet iSCSI ports per G3 iSCSI controller
Modular Chassis 2U rack height. 12 Large Form Factor or 24 Small Form Factor drive bays, accommodating SAS and SATA. Comes with space for one or two controllers, or P2000
DA - 13551 Worldwide QuickSpecs — Version 12 — 2/7/2011 | Page 9 |