QuickSpecs

HP dc72 Blade Workstation Client

Technical Specifications

Unit Environment and Operating Conditions

General Unit Operating Guidelines

Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is operated within the specified operating range.

Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow. Never restrict airflow into the computer by blocking any vents or air intakes.

Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re- circulated or preheated air.

Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign matter can block the vents and limit the airflow.

If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure, and the same operating guidelines listed above will still apply.

Temperature Range

Operating: 50° to 95° F (10° to 35° C)*

Non-operating: -22° to 140° F(-30° to 60° C)

Relative Humidity

Operating: 10% to 90% (non-condensing at ambient)

Non-operating: 5% to 95% (non-condensing at ambient)

Maximum Altitude (unpressurized)

Operating: 10,000 ft (3048 m)

Non-operating: 30,000 ft (9144 m)

*NOTE: Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.

Power Supply

Power Supply

240 watt custom power supply - Active PFC

Operating Voltage Range

90 - 264 VAC

Rated Voltage Range

100 - 240 VAC

Rated Line Frequency

50/60 Hz

Operating Line Frequency Range

47 - 63 Hz

Rated Input Current

5A

System Heat Dissipation

Typical 340 btu/hr

 

(86 kg-cal/hr)

 

Maximum 1260 btu/hr

 

(318 kg-cal/hr

Power Supply Fan

80mm variable speed

Energy Star 3.0 Compliant

X

FEMP Standby Power Compliant

X

(<2W in S5 - Power Off)**

 

Power Consumption in ES Mode - Suspend

< 3W

to RAM (S3) (Instantly Available PC)

 

Environmental and Mechanical Engineering http://env-webserver.ccm.cpqcorp.net/EMESC/default.htm Support Centre (EMESC) - Intranet Web

Site only

**NOTE: Power consumption in the Off/Apparent Off mode is measured and reported with the network interface controller "Wake on LAN" feature disabled in F10 Setup (default is "enabled").