Error Messages and Codes

A.19 SCSI Interface Error Messages (65xx-xx, 66xx-xx, 67xx-xx)

Table A-18

SCSI Interface Error Messages

Message

Probable Cause

Message

Probable Cause

 

 

 

 

6nyy-02

Drive not installed

6nyy-33

Illegal controller command

 

 

 

 

6nyy-03

Media not installed

6nyy-34

Invalid SCSI bus phase

 

 

 

 

6nyy-05

Seek failure

6nyy-35

Invalid SCSI bus phase

 

 

 

 

6nyy-06

Drive timed out

6nyy-36

Invalid SCSI bus phase

 

 

 

 

6nyy-07

Drive busy

6nyy-39

Error status from drive

 

 

 

 

6nyy-08

Drive already reserved

6nyy-40

Drive timed out

 

 

 

 

6nyy-09

Reserved

6nyy-41

SSI bus stayed busy

 

 

 

 

6nyy-10

Reserved

6nyy-42

ACK/REQ lines bad

 

 

 

 

6nyy-11

Media soft error

6nyy-43

ACK did not deassert

 

 

 

 

6nyy-12

Drive not ready

6nyy-44

Parity error

 

 

 

 

6nyy-13

Media error

6nyy-50

Data pins bad

 

 

 

 

6nyy-14

Drive hardware error

6nyy-51

Data line 7 bad

 

 

 

 

6nyy-15

Illegal drive command

6nyy-52

MSG, C/D, or I/O lines bad

 

 

 

 

6nyy-16

Media was changed

6nyy-53

BSY never went busy

 

 

 

 

6nyy-17

Tape write-protected

6nyy-54

BSY stayed busy

 

 

 

 

6nyy-18

No data detected

6nyy-60

Controller CONFIG-1 register fault

 

 

 

 

6nyy-21

Drive command aborted

6nyy-61

Controller CONFIG-2 register fault

 

 

 

 

6nyy-24

Media hard error

6nyy-65

Media not unloaded

 

 

 

 

6nyy-25

Reserved

6nyy-90

Fan failure

 

 

 

 

6nyy-30

Controller timed out

6nyy-91

Over temperature condition

 

 

 

 

6nyy-31

Unrecoverable error

6nyy-92

Side panel not installed

 

 

 

 

6nyy-32

Controller/drive not connected

6nyy-99

Autoloader reported tape not loaded properly

 

 

 

 

n = 5, Hard drive

= 6, CD-ROM drive = 7, Tape drive

yy = 00, ID

= 03, Power check = 05, Read

= 06, SA/Media

= 08, Controller

= 23, Random read

= 28, Media load/unload

 

A-18

www.hp.com

Technical Reference Guide