POST Error Messages Continued |
|
|
Screen Message | Beeps* | Probable Cause |
None | Hard drive is about to fail. | |
Detects Imminent Failure |
| (Some hard drives have a |
|
| firmware patch that will fix |
|
| an erroneous error |
|
| message.) |
None | Hard drive is about to fail. | |
Drive Detects Imminent |
| (Some hard drives have a |
Failure |
| firmware patch that will fix |
|
| an erroneous error |
|
| message.) |
2S | Internal and external hard | |
Address Assignment |
| drive controllers are both |
Conflict |
| assigned to the primary |
|
| address. |
Recommended Action
1.Determine if hard drive is giving correct error message. Run the Drive Protection System test available.
2.Apply firmware patch if applicable.
3.Back up contents and replace hard drive.
1.Determine if hard drive is giving correct error message. Run the Drive Protection System test available.
2.Apply firmware patch if applicable.
3.Back up contents and replace hard drive.
1.Remove any Comm port expansion cards.
2.Clear CMOS.
3.Reconfigure card resources and/or run Computer Setup (F10 Setup).
2S | Internal and external hard | |
Address Assignment |
| drive controllers are both |
Conflict |
| assigned to the primary |
|
| address. |
1.Remove any Comm port expansion cards.
2.Clear CMOS.
3.Reconfigure card resources and/or run Computer Setup (F10 Setup).
None | Hard drive/format error. | 1. | Run Computer Setup (F10 | |
|
|
|
| Setup). |
|
|
| 2. | Clear CMOS. |
|
|
| 3. | Check cables/jumper settings. |
|
|
| 4. | Run hard drive diagnostics. |
|
|
| 5. | Disconnect additional drives. |
|
|
| 6. | Run the Drive Protection |
|
|
|
| System test if available. |
|
|
| 7. | Replace the hard drive. |
* L = Long, S = Short |
|
|
| continued |