Appendix A Product Specifications

SCSI Command Set (Cont'd)

Mode Sense

Load/Unload

Receive Diagnostic Results

Send Diagnostics

Prevent/Allow Medium Removal

Verify

Locate

Read Position

Log Sense/Log Select

Environment

Operating temperature: +5°C to +40°C (+41°F to 104°F)

Non-operating temperature: -40°C to +60°C (-40°F to +140°F)

Relative humidity (noncondensing): 20% to 80%

SCSI Characteristics

SCSI-2 Specification — ANSI X3.131-1990

Sequential Access Device

SCSI Bus Parity — Configurable

Full Disconnect, Arbitration, Reconnect

Asynchronous and Synchronous Data Transfer Supported

Connector Type — Standard StorageWorks Connector

Termination — None

Single-Ended

Physical Dimensions (Tape Device)

Standard 5.25-inch half-high form factor

Height: 1.625 inch

Width: 5.750 inch

Depth: 8.0 inch

Weight: 2.57 pounds

Power (For One Tape Device)

+5/ +12 volts plus or minus 5%

15 watts

Order Number: EK–STWCT–UG. E01