QuickSpecs

HP ProLiant ML115

System Specifications

 

Power **

HP ProLiant ML115 Fully Configured

(see **)

Fully Loaded System output Wattage

370W

(W)

 

Fully Loaded System Input Current (A

8A @ 115V, 4A @ 230V

rms)

 

Fully Loaded System Thermal (BTU- Hr)

1907BTU

Fully Loaded System VA (Volt-Amp)

920

System Leakage with all power supplies

0.75mA@240V

loaded (mA)

0.45mA@120V

System Inrush Current with all power

80A

supplies loaded (A)

 

Power cord requirements

Nema 5-15P to IEC320-C13

 

IEC320-C13 to IEC320-C14

 

**Power shown is for a fully configured system consisting of (1) CPU, (4) double-sided

 

DIMMs, (4) HDDs, (1) CD-ROM, (1) DVD-ROM, (4) PCI cards, and (1) power supply.

 

 

Power Cords (13 Cord Sets)

Power Cord Part Number

Country

 

APD

100614-009, 100613-008, 139867-004, 187487-004 (India)

Brazil

285052-001

Australia

100661-001

Euro

100614-009

France

100614-009

Germany

100614-009

Japan

139867-004

PRC

286496-001

UK

100613-008

US, Taiwan

121565-001

DA - 12704 Worldwide — Version 16 — May 12, 2008