Quick Start Guide |
ProCurve Secure Router 7203dl
J8753A
ENABLE TELNET ACCESS
The following steps create an IP address (2.2.2.1 /24) for Ethernet port 0/1, an enable password of enablepw, and a password of secretpw for Telnet access.
1.At the (config)# prompt, enter interface eth 0/1 to access the configuration parameters for the Ethernet port located on the base unit.
2.Enter ip address 2.2.2.1 /24 to assign an IP address to the Ethernet port using a
3.Enter no shutdown to activate the interface to pass data.
4.Enter exit to exit the Ethernet interface commands and return to the Global Configuration mode.
5.Verify that the prompt of your unit displays (config)#.
6.Enter line telnet 0 4 to change the configuration parameters for the Telnet session.
7.Enter login to initiate Telnet access.
8.Enter password secretpw to change the login password for the Telnet session.
CONSOLE PINOUT
Pin | Name | Description |
|
|
|
1 | — | Unused |
2 | RD | Receive Data (input) |
3 | TD | Transmit Data (output) |
4 | DTR | Data Terminal Ready (output) |
5 | SG | Signal Ground |
6 | DSR | Data Set Ready (input) |
7 | RTS | Request to Send (output) |
8 | CTS | Clear to Send (input) |
9 | — | Unused |
9.Enter exit to return to the Global Configuration mode.
10.Verify that the prompt of your unit displays (config)#.
11.Enter enable password enablepw to set the Enable Security mode password.
12.Enter exit to return to the Enable mode.
13.Enter write memory to save the current configuration to memory.
ENABLE WEB GUI ACCESS
To enable Web GUI access, an IP address for an Ethernet port must be assigned. Refer to Enable Telnet Access above. HTTP and HTTPS are enabled by default but a username and password must be configured. The example below creates a username of manager and a password of webpw. Once configured, use a Web browser to access the IP address.
1.Verify that the prompt of your unit displays (config)#.
2.Enter username manager password webpw to set the password.
3.Enter exit to return to the Enable mode.
4.Enter write memory to save the current configuration to memory.
5.Open your web browser, and enter the unit’s IP address into the browser address line (e.g., http://2.2.2.1).
ETHERNET PINOUT
Pin | Name | Description |
|
|
|
1 | TX1 | Transmit Positive |
2 | TX2 | Transmit Negative |
3 | RX1 | Receive Positive |
4, 5 | — | Unused |
6 | RX2 | Receive Negative |
7, 8 | — | Unused |
COMMANDS
Refer to the SROS Command Line Interface Reference Guide (provided on the SROS ProCurve Documentation CD) for details on configuring the system using the command line interface.
Note For safety information for the routers and all modules, please refer to the safety and ESD precautions in the ProCurve Secure Router Installation Guide included in your router shipment.
Printed in the USA | Copyright 2005 |