configuration information from the active module. It remains as the standby until either a system administrator manually promotes it to the active module or the active module fails.
General HP BladeSystem I/O Redundancy ConsiderationsHP Integrity server blades I/O connectivity provides for:
∙2 LAN on Motherboard (LOM) modules (2 ports each @ 1Gb/s; 4 ports total)
∙Support for up to 3 Mezzanine cards
With this hardware connectivity, it is possible to use a combination of LOM ports and Mezzanine cards to provide redundancy for both network and storage connections to the server blade. HP recommends configuring primary and alternate paths to use different Mezzanine cards and interconnect modules to eliminate these components as potential SPOFs, if possible. However; depending on the Mezzanine card configuration chosen based on customer availability requirements and cost, it is acceptable to have both primary and alternate paths defined through one
With the four internal Ethernet ports provided on Integrity server blades using two LOM NICs that have independent hardware port controllers, it is possible to create a redundant networking configuration that eliminates the blade networking ports as a SPOF. This is achieved by configuring the LOM ports to avoid a potential port controller failure that could disable two ports by using ports 1 and 4 as the Serviceguard primary and standby connection for one network (e.g., site data LAN) and ports 2 and 3 as the primary and standby connection for another network (e.g., Serviceguard heartbeat). Using this configuration, Serviceguard local LAN failover would protect against either a port controller or interconnect module failure. Note that it is also possible to use APA
HP also recommends using an additional
Using redundant HP Virtual Connect (VC) Ethernet modules is another method to improve network connection availability. VC Ethernet modules, when installed in a
Virtual Connect also facilitates Ethernet link failover by allowing Virtual Connect networks to utilize ports on multiple Virtual Connect modules in the same VC Domain. VC domains using Virtual Connect Manager can span up to four enclosures; additional enclosures can be managed using Virtual Connect Enterprise Manager. Depending on the configuration, a VC network will transparently shift its upstream communication to a port on the same module or on a different module in the event of a link failure. HP recommends using fully redundant interconnection of Virtual Connect Ethernet modules so that, if a stacking cable is lost, Ethernet packets within the VC domain will be automatically rerouted to the uplink through the redundant path. This connection also preserves network connectivity if an Ethernet interconnect module fails or is removed. Figure 8 shows an example of stacked Virtual Connect Ethernet modules.