For more information on setting this parameter, see the Serviceguard Network Manager Inbound Failure Detection white paper at: http://docs.hp.com/en/5568/serviceguard.network.manager.pdf

This issue also affects HP-UX APA (Auto-Port Aggregation) link aggregates and APA failover groups (LAN_MONITOR mode)

This hardware issue and a list of available solutions is documented in the HP Support Communication Customer Advisory at: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c01814615&lang=en&cc =us&taskId=101&prodSeriesId=3676868&prodTypeId=3709945

Recommend using network ports from different LOM port controllers for redundant active/standby Serviceguard site and heartbeat network configurations

Fibre Channel Connectivity:

Each server blade must have at least 1 Mezzanine card for Fiber Channel connectivity

If a server blade has 2 or more Fiber Channel Mezzanine cards, it is recommended that the primary and alternate Fiber Channel paths use different Mezzanine cards to prevent a Mezzanine card from being a single point of failure

Virtual Connect:

Uplinks between Virtual Connect modules can be used for private cluster heartbeat networks between blade enclosures (note stacking links between adjacent VC Ethernet modules is internal)

Note when using dedicated internal cluster heartbeat networks, it can be difficult to test cluster failover due to a loss of heartbeat as there is no physical LAN cable available to disconnect

Flex-10:

The HP NC532m Dual Port 10GbE BL-c Adapter is supported with HP-UX and Serviceguard

Can use the 1Gb Ethernet Mezzanine or LOM with the HP BLc Virtual Connect Flex-10 10Gb Ethernet interconnect module (figure 14) with server blades running either HP-UX or Windows

The Flex-10 module will only operate as a 1Gb, non-Flex-10 module for HP-UX. While it cannot take advantage of some Flex-10 features; it can be used at 1Gb and is supported with HP-UX and Serviceguard.

Figure 14: HP BLc Virtual Connect Flex-10 10Gb Ethernet Interconnect Module

23