QuickSpecs

HP Z400 Workstation

System Technical Specifications

Declared Noise Emissions

 

Sound Power ( LWAd, bels )

 

Deskside Sound Pressure

(in accordance with ISO

Idle

3.9 Bels

 

23 dB

7779 and ISO 9296)

SATA Hard drive

4.2 Bels

 

25 dB

 

 

 

Operating (random reads)

 

 

 

 

Floppy Drive Operating

4.7 Bels

 

29 dB

 

(continuous copy)

 

 

 

 

DVD-ROM Operating

5.1 Bels

 

38 dB

 

(sequential reads)

 

 

 

 

 

 

 

System Configuration

Processor Info

Intel Xeon Processor W3570 3.20 GHz

 

(High-end)

Memory Info

4 x 1GB DDR3 1333 MHz

 

 

Graphics Info

NVIDIA Quadro FX 4600

 

 

Disks/Optical/Floppy

2 x 450 GB 15K SAS / DVD-ROM / No Floppy

 

 

 

Declared Noise Emissions

 

Sound Power ( LWAd, bels )

 

Deskside Sound Pressure

(in accordance with ISO

Idle

4.6 Bels

 

27 dB

7779 and ISO 9296)

SATA Hard drive

5.2 Bels

 

35 dB

 

 

 

Operating (random reads)

 

 

 

 

Floppy Drive Operating

5.0 Bels

 

32 dB

 

(continuous copy)

 

 

 

 

DVD-ROM Operating

5.3 Bels

 

38 dB

 

(sequential reads)

 

 

 

 

 

 

 

Environmental

Temperature

Operating: 40° to 95° F (5° to 35° C)

 

Requirements

 

Non-operating: -40° to 140° F (-40° to 60° C)

 

Humidity

Operating: 8% to 85% RH, non-condensing

 

 

 

Non-operating: 8% to 90% RH, non-condensing

 

Maximum Altitude

Operating: 10,000 feet (3,000 m)

 

 

 

Non-operating: 30,000 feet (9,100 m)

 

 

Dynamic (new)

Shock

 

 

 

Operating: ½-sine: 40g, 2-3ms

 

 

 

Non-operating:

 

 

 

½-sine: 160 cm/s, 2-3ms (~100g)

 

 

 

square: 422 cm/s, 20g

 

 

 

NOTE: Values represent individual shock events and do not indicate

 

 

repetitive shock events.

 

 

 

Vibration

 

 

 

Operating random: 0.5g (rms), 5-300 Hz

 

 

 

Non-operating random: 2.0g (rms), 10-500 Hz

 

 

NOTE: Values do not indicate continuous vibration.

 

Cooling

Above 5000 ft (1524 m) altitude, maximum operating temperature is de-

 

 

rated by 1.8° F (1° C) per 1000 ft (305 m) elevation increase

 

 

 

 

Physical Security and Serviceability

 

 

 

 

 

DA - 13276 Worldwide QuickSpecs — Version 1 — 3.30.2009

Page 19

Page 19
Image 19
HP Z400 manual Non-operating 8% to 90% RH, non-condensing, Repetitive shock events