Hubbell 31200 Specifications, Hubbell Offers, Pneumatic Cabinet, Radio Receiver, Control Section

Models: 31200

1 4
Download 4 pages 53.19 Kb
Page 3
Image 3
Pneumatic Cabinet

comotive magnetics and pneumatic systems in re- sponse to decoded control commands. The configura- tion of the manual control switches is duplicated and wired to industrially rated terminals for interconnec- tion to the locomotive con- trols. A manual-remote transfer switch is provided to completely isolate the radio system from the man- ual controllers.

The receiver antenna is normally mounted on the locomotive cab, and suffi- cient co-axial cable is pro- vided to connect the an- tenna to the radio receiver module in the cabinet.

Pneumatic Cabinet

The pneumatics enclosure is of NEMA 12 construc- tion and houses the pneu- matic controls for the re- mote operation of the lo- comotive. The locomotive throttle, independent brakes, and the train line brakes are normally oper- ated via binary pneumatic valves for control of the air pressure. Other functions and the horn are con- trolled by solenoid valves. This cabinet also contains the pressure switches for main air, independent brakes air, train line brakes air, and throttle air.

Specifications

Supply Voltage

12VDC, 24VDC, 36VDC or 72VDC

Internal Power Requirements

+11.9–13.1VDC & +4.5–6.5VDC

Operating Temperature

–22°F (–30°C) to 140°F (+60°C)

Radio Receiver

Frequency Range

72–76 MHz or 450–470 MHz

Channel Availability

as required by user

Frequency Stability

±5 ppm

Sensitivity

1 µv @ 20 dB quieting

Data Reception

compatible with existing transmitters

Modulation

biphase

Baud Rate

4800 bps

Message Format

preamble, sync pattern, start flag, address, control, CRC

 

check code

Control Section

Single board computer consisting of 80C31BH controller, 64k EPROM, EPLD containing cir- cuits for message synchronizing, and processor watchdog

Hubbell Offers

Factory Assembled — the transmitter, receiver, and pneumatics cabinets are completely as- sembled and wired at the Hubbell factory.

System Test — the entire system is tested for a minimum of 48 hours prior to shipment.

Installation and Commissioning — Installation is accomplished quickly. Transfer switch is pre-wired and labeled, interconnecting termi- nals are provided to simplify installation. A Hubbell field engineer can be contracted for installation and final check-out.

Customer Support — Hubbell provides a complete documentation package including drawings, operating manuals, service manu- als, spare parts, training and experienced field service engineers.

Switches

8 position address dip, 4 position message timer dip

Indicators

2 digit display (7 segment LED) for self diagnostics & error

 

conditions

Firmware

written in 8031 assembly language structured for ease of

 

customization of output control

Functions

message input address decoding, error checking, control

 

bit decoding, output control self diagnosis

Paralleled I/O

basic system uses single board, up to three additional

 

boards may be added

Output per board

48 software programmable for input or output with

 

readback on all outputs

Driver per output

TTL compatible for up to 25mA sink

DC Output Section

Solid state relay PC boards in card cage.

Type

Opto Isolated

Indicators

Red: output activated

Output Voltage

24VDC

Input Voltage

4.5–6.5Vdc, active high

Load

0.5A, 24VDC, inductive

Isolation

1500V

Input Board

Input 24 VDC sensing PC board in card cage.

Indicator

Red: input activated

Input

24VDC nominal

Isolation

1500V input to output & between circuits

Output

Opto-isolated; active low

HUBBELL

Page 3
Image 3
Hubbell 31200 Specifications, Hubbell Offers, Pneumatic Cabinet, Radio Receiver, Control Section, DC Output Section