IMMERSION TEMPERATURE HIGH LIMIT CUT-OFF

IMMERSION TEMPERATURE HIGH LIMIT CUT-OFF

1.Disconnect power from unit.

2.Remove access cover.

3.Remove high limit cover screw and cover.

Cover

Cover Screw

Reset Switch Manual background

4. Disconnect the two (2) 14 gauge wires.

Wires Manual background

Capillary Tube

5. Remove capillary tube and bulb from thermowell

6. Remove two (2) mounting screws.

Mounting Screws Manual background

7.Remove control and install new high limit switch by performing above steps in reverse order. (Note: Be sure to place capillary tube into slot in base prior to installing cover.)