SECTION V - SERVICING & REPLACEMENT OF PARTS

WARNING / CAUTION

Before servicing or replacing any part make sure to turn the power supply switch to the OFF position.

SURFACE TEMPERATURE HIGH LIMIT CUT-OFF

1.Disconnect power from unit.

2.Remove access cover.

3.Disconnect the four (4) 14 gauge wires or three (3) 14 gauge wires and a jumper, as required.

Control Wires

High-Limit Cut-Off Switch

Manual Reset

Control Wires

Temperature Controller

4.Disconnect the high-limit cut-off switch from the temperature controller by pulling the cut- off switch up and away from temperature controller.

5.Replace control and install new high limit switch by performing above steps in reverse order.

13

Page 13
Image 13
Hubbell Electric Heater Company E manual Section V Servicing & Replacement of Parts, Surface Temperature High Limit CUT-OFF