ANNUAL INSPECTION

1.Flush tank as follows

a.Shut off power supply.

b.Close valve on hot water outlet piping.

c.Open valve on drain piping.

d.Cold water inlet line pressure will be strong enough to flush sediment from the bottom of the tank out through the drain. Let water run for 3-4 minutes.

e.Close drain valve.

f.Open hot water valve.

g.Turn power supply ON.

11

Page 11
Image 11
Hubbell Electric Heater Company E Annual Inspection, Flush tank as follows a.Shut off power supply, g.Turn power supply ON