SURFACE MOUNTED THERMOSTAT (if supplied)

SURFACE MOUNTED THERMOSTAT (if supplied)

1.Disconnect power from unit.

2.Remove access cover and locate thermostat.

3.Disconnect the two (2) or three (3) 14 gauge wires and jumpers, as required.

Control Wires 2.Remove access cover and locate thermostat.

4. Remove two (2) mounting screws and disconnect from high limit cut-off, if required.

Mounting Screws 5. Replace thermostat using the reverse procedure.

5. Replace thermostat using the reverse procedure.