CHECKING TIP CLEARANCE

After mounting, install flat washer, lock washer, and 3/8” NC nuts. Tighten to 15 ft-lb (lubricated) or 20 ft-lb (dry). (See Figure 7)

Note: Refer to instructions included with seal disc for further details.

Figure 7

CHECKING TIP CLEARANCE

Rotate fan in position inside fan stack to check tip clearance (See Figure 8). The recommended tip clearance is between 1” and 1 1/2 ”. Check for spots where fan blade clearance is not within the recommended tolerance. If necessary adjust fan stack by shimming to obtain proper clearance.

Figure 8

OPERATING INSTRUCTIONS

Start fan and check rotation. Viewed from top (discharge), fan blades should rotate clockwise.

Check motor power consumption to be sure fan is pulling desired load. CAUTION: If positive pitch is set in summer to use all available motor amps (nameplate rating), motor could be over- loaded in winter. Design pitch angles usually do not use all avail-

able horsepower; therefore, motors will not be overloaded at lowest winter temperatures.