Hunter Fan 2A installation manual Installing the Hanger Bracket

Models: 2A

1 13
Download 13 pages 10.89 Kb
Page 5
Image 5
2 • Installing the Hanger Bracket

2 • Installing the Hanger Bracket

isolators between the hanger bracket and ceiling by inserting the CAUTION: To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.

2-1. Drill two pilot holes into the wood support structure through the outermost holes in the outlet box. The pilot holes should be 9/64” in diameter.

2-2. Partially install two canopy screws in the holes on each end of the hanger bracket, as shown in the figure to the right.

Hanger

 

Bracket

 

Canopy

 

Screw

Step 2-2

 

Thread the lead wires from the outlet box down through the hole Canopy Screw

2-3.

Your fan comes with four mounting isolators. Position the

 

 

isolators between the hanger bracket and ceiling by inserting the

 

 

raised areas on each isolator into the holes in the hanger bracket.

Isolator

 

 

2-4.

Thread the lead wires from the outlet box down through the hole

 

 

in the middle of the hanger bracket.

Step 2-3

2-5.

Align the slotted holes in the hanger bracket with the pilot holes

 

 

you drilled in the wood support structure.

 

 

Note: The isolators should be flush against the ceiling.

 

2-6.

Place a flat washer on each of the two 3” wood screws and pass

 

 

the screws through the slotted holes in the hanger bracket into

 

 

the pilot holes you drilled.

 

 

Tighten the screws into the 9/64” pilot holes; do not use lubricants

 

 

on the screws. Do not over tighten.

 

 

Flat Washer

 

 

3” Wood Screw

 

 

 

Steps 2-42-6

5

42883-01 • 08/27/09 • Hunter Fan Company

Page 5
Image 5
Hunter Fan 2A Installing the Hanger Bracket, isolators between the hanger bracket and ceiling by inserting the