! W a r n i n g

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer.

2.Before servicing or cleaning the unit, switch power off at ser- vice panel and lock the service disconnecting means to prevent power from being switched on accidentally. when the service disconnecting means cannot be locked, securely fasten a promi- nent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

4.Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufac- turer’s guideline and safety standards,such as those published by the National Fire Prevention Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning

Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

8.Never place a switch where it can be reached from a tub or shower.

9.Install fan at least 5 feet (1.52 m) above the floor.

10.This unit must be grounded.

11.Unit must not be installed in a ceiling thermally insulated to a value greater than R40.

!C A U T I O N

1.For general ventilating use only. Do not use to exhaust haz- ardous or explosive materials and vapors.

2.To avoid motor bearing damage and noisy/unbalanced impel- lers, keep drywall spray, construction dust, etc. off power unit.

3.DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward.

4.Please read specification label on product for further infor- mation and requirements.

!W a r n i n g

DISCONNECT ELECTRIC

POWER SUPPLY

AND LOCK OUT

SERVICE PANEL BEFORE

SERVICING UNIT

PREVENTATIVE MAINTENANCE

A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.

TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.

TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove

motor plate, find the single tab on the motor plate (located next to the recepta- cle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screw- driver. Gently vacuum fan, motor and interior of housing.

METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.

MAINTENANCE

The motor is permanently lubricated and never needs oiling. If the motor bear- ings are making excessive or unusual

noises, replace the motor with the exact service motor. You should replace the impeller at the same time.

COOKING AREA

 

Do Not Install Above

 

Or Inside This Area

 

45°

45°

 

 

Cooking

Floor

 

 

 

Equipment

 

2

43043-01 01/24/2008

Page 2
Image 2
Hunter Fan 81030 manual Preventative Maintenance

81030 specifications

The Hunter Fan Company has long been a trusted name in ceiling fans, and the Hunter Fan 81030 is a notable addition to their lineup. Designed with both style and efficiency in mind, this ceiling fan blends modern aesthetics with advanced technology to enhance any room's ambiance.

One of the main features of the Hunter Fan 81030 is its sleek, contemporary design. It typically boasts a clean, streamlined look available in various finishes that can complement any decor, from minimalist to more traditional settings. The fan's blades are crafted from high-quality materials, ensuring durability while also providing optimal airflow.

Equipped with WhisperWind motor technology, the Hunter Fan 81030 offers powerful yet quiet performance. This innovative motor enables the fan to deliver a strong breeze without the disruptive noise often associated with ceiling fans. As a result, it creates an inviting atmosphere perfect for any space, whether it's a living room, bedroom, or office.

The fan's reversible motor is another significant characteristic, allowing users to change the direction of blade rotation. In summer, it can spin counterclockwise to create a cooling breeze, while in winter, reversing the direction helps circulate warm air that rises, improving heating efficiency. This versatility makes it a year-round solution for climate control.

Energy efficiency is a crucial consideration for many consumers today, and the Hunter Fan 81030 excels in this area. It is designed to consume less power while delivering high airflow, ultimately helping to reduce energy costs. Additionally, this fan is often compatible with smart home systems, allowing users to control it via smartphone apps or voice assistants, providing an extra layer of convenience.

Installation is straightforward, aided by a comprehensive manual that guides users through the process. Many versions of the Hunter Fan 81030 come with an integrated lighting option, allowing for a cohesive look in your space while also providing illumination.

In summary, the Hunter Fan 81030 stands out in the market due to its combination of style, performance, and energy efficiency. With its WhisperWind motor, reversible capabilities, smart home compatibility, and easy installation, it is a fantastic choice for anyone looking to enhance their home or office with a ceiling fan that meets modern standards of comfort and design.