W a r n i n g

TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:

1.Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer at the phone number or address listed in the warranty.

2.Before installing, servicing, or cleaning the unit, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely attach a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhaust- ing of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards,

such as those published by the National Fire Prevention Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities.

6.Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible.

7.Acceptable for use over a bathtub or shower when connected to a GFCI protected branch circuit.

8.Install fan at least 5 feet (1.52 m) above the floor.

9.Never place a switch where it can be reached from a tub or shower.

10.This unit must be grounded.

C A U T I O N

1.For general ventilating use only. Do not use for ventilat- ing hazardous or explosive materials.

2.To avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

3.DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward.

4.Please read specification label on product for further information and requirements.

W a r n i n g

DISCONNECT

ELECTRIC

POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT

PREVENTATIVE MAINTENANCE

A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.

TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.

TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.

METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.

MAINTENANCE

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time.

2

41945-01 3/29/2006

05-HF-021-EngS_3.29.06.indd 2

3/29/06 7:15:32 PM

Page 2
Image 2
Hunter Fan 82003 manual Preventative Maintenance

82003 specifications

The Hunter Fan 82003 is a finely crafted ceiling fan designed for both functionality and elegance, making it an ideal choice for a variety of indoor settings. Hunter Fan Company, a renowned name in the industry, combines quality craftsmanship with modern technology in this model, ensuring optimal performance and aesthetics.

One of the standout features of the Hunter Fan 82003 is its powerful yet efficient motor. The fan operates quietly while providing powerful airflow, which can effectively circulate air in both large and small rooms. This makes it an ideal option for living rooms, bedrooms, or dining areas, enhancing comfort year-round.

The fan is designed with a sleek, contemporary style that can seamlessly blend into various décor themes. It is available in multiple finishes, allowing homeowners to select one that best complements their interiors. The fan's blades, typically made of quality wood or composite materials, are designed to provide maximum durability and performance, ensuring they hold up over time without warping or fading.

Additionally, the Hunter Fan 82003 incorporates advanced technological features like the WhisperWind motor, delivering a serene atmosphere by minimizing noise levels. This is particularly beneficial for bedrooms or home offices where a quiet environment is essential. The fan also boasts a reversible motor option, allowing for year-round use; it can circulate warm air in the winter while providing cooling breezes in the summer, enhancing energy efficiency and comfort.

Installation of the Hunter Fan 82003 is designed to be straightforward, with a simple setup that can typically be completed by homeowners themselves. It is compatible with various Hunter Fan light kits, allowing for added illumination that can be adjusted according to the ambiance desired.

Furthermore, Hunter Fans are known for their commitment to sustainability, using materials and manufacturing processes that reflect an eco-conscious approach. This model is designed with energy efficiency in mind, helping to reduce electricity bills while still providing effective airflow.

In summary, the Hunter Fan 82003 encapsulates style, efficiency, and innovation in a ceiling fan. With its quiet motor, versatile design, and effective airflow capabilities, it stands out as an excellent choice for anyone looking to enhance their living space with a reliable and stylish ceiling fan. Its blend of features ensures comfort and satisfaction for years to come.