Fuel Valve Maintenance
The fuel valve is equipped with a fuel sediment cup, screen, retaining ring and
1.Move fuel valve to “Off” position.
2.Remove sediment cup (A) from fuel valve. Remove
D |
C |
B |
A |
3.Wash sediment cup,
4.Place screen, retaining ring, and
5.Move fuel valve to “On” position, and check for leaks. Replace
Engine Maintenance
warning
Unintentional sparking can result in fire or electric shock.
When adjusting or making repairs to your generator
•Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
•Use approved spark plug tester.
•DO NOT check for spark with spark plug removed.
Oil
Oil Recommendations
We recommend the use of Briggs & Stratton Warranty Certified oils for best performance. Other
Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the outdoor temperature range expected.
*Below 40°F (4°C) the use of SAE 30 will result in hard starting.
**Above 80°F (27°C) the use of 10W30 may cause increased oil consumption. Check oil level more frequently.
NOTE: Synthetic oil meeting ILSAC
Checking Oil Level
Oil level should be checked prior to each use or at least every 8 hours of operation. Keep oil level maintained.
1.Make sure generator is on a level surface.
2.Clean area around oil fill and remove oil fill cap.
3.Verify oil is at the point of overflowing at oil fill opening.
4.Replace and tighten oil fill cap.
Adding Engine Oil
1.Make sure generator is on a level surface.
2.Check oil level as described in Checking Oil Level.
3.If needed, slowly pour oil into oil fill opening to the point of overflowing at oil fill.
4.Replace and tighten oil fill cap.
16 | www.usa.husqvarna.com |