Husqvarna 96045002700 Engine, Transaxle Cooling, Transaxle Pump Fluid, V-Belts, Lubrication

Models: 532 43 86-44 96045002700

1 48
Download 48 pages 432 b
Page 16
Image 16
TRANSAXLE COOLING

MAINTENANCE

TRANSAXLE COOLING

The transmission fan and cooling fins should be kept clean to assure proper cooling.

Do not attempt to clean fan or transmission while engine is running or while the transmission is hot. To prevent pos- sible damage to seals, do not use high pressure water or steam to clean transaxle.

Inspect cooling fan to be sure fan blades are intact and clean.

Inspect cooling fins for dirt, grass clippings and other materials. To prevent damage to seals, do not use compressed air or high pressure sprayer to clean cooling fins.

TRANSAXLE PUMP FLUID

The transaxle was sealed at the factory and fluid mainte- nance is not required for the life of the transaxle. Should the transaxle ever leak or require servicing, contact your nearest authorized service center/department.

V-BELTS

Check V-belts for deterioration and wear after 100 hours of operation and replace if necessary. The belts are not adjustable. Replace belts if they begin to slip from wear.

ENGINE

LUBRICATION

Only use high quality detergent oil rated with API service classification SG-SL. Select the oil’s SAE viscosity grade according to your expected operating temperature.

SAE VISCOSITY GRADES

 

 

 

 

 

 

 

 

 

 

SAE 30

 

 

 

 

 

 

5W-30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

-20

0

 

 

30 32 40

 

60

80

100

C

-30

-20

-10

0

10

20

30

40

TEMPERATURE RANGE ANTICIPATED BEFORE NEXT OIL CHANGE

oil_visc_chart1_e

Fig. 14

NOTE: Although multi-viscosity oils (5W30, 10W30 etc.) improve starting in cold weather, they will result in increased oil consumption when used above 32°F/0°C. Check your engine oil level more frequently to avoid possible engine damage from running low on oil.

Change the oil after every 50 hours of operation or at least once a year if the tractor is not used for 50 hours in one year.

Check the crankcase oil level before starting the engine and after each eight (8) hours of operation. Tighten oil fill cap/dipstick securely each time you check the oil level.

TO CHANGE ENGINE OIL (See Figs. 14 and 15)

Determine temperature range expected before oil change. All oil must meet API service classification SG-SL.

Be sure tractor is on level surface.

Oil will drain more freely when warm.

Catch oil in a suitable container.

Remove oil fill cap/dipstick. Be careful not to allow dirt to enter the engine when changing oil.

Remove yellow cap from end of drain valve and install the drain tube onto the fitting.

Unlock drain valve by pushing inward and turning counterclockwise.

To open, pull out on the drain valve.

After oil has drained completely, close and lock the drain valve by pushing inward and turning clockwise until the pin is in the locked position as shown.

Remove the drain tube and replace the cap onto to the bottom fitting of the drain valve.

 

OIL DRAIN VALVE

CLOSED

 

AND

 

LOCKED

 

POSITION

 

YELLOW CAP

DRAIN

TUBE

 

 

Fig. 15

Refill engine with oil through oil fill dipstick tube. Pour slowly. Do not overfill. For approximate capacity see “PRODUCT SPECIFICATIONS” section of this manual.

Use gauge on oil fill cap/dipstick for checking level. Insert dipstick into the tube and rest the oil fill cap on the tube. Do not thread the cap onto the tube when taking reading. Keep oil at “FULL” line on dipstick. Tighten cap onto the tube securely when finished.

ENGINE OIL FILTER

Replace the engine oil filter every season or every other oil change if the tractor is used more than 100 hours in one year. See engine manual.

AIR FILTER

Your engine will not run properly using a dirty air filter. Service air cleaner more often under dusty conditions. See Engine Manual.

CLEAN AIR SCREEN

Air screen must be kept free of dirt and chaff to prevent engine damage from overheating. Clean with a wire brush or compressed air to remove dirt and stubborn dried gum fibers.

MUFFLER

Inspect and replace corroded muffler and spark arrester (if equipped) as it could create a fire hazard and/or damage.

SPARK PLUGS

Replace spark plugs at the beginning of each mowing season or after every 100 hours of operation, whichever occurs first. Spark plug type and gap setting are shown in “PRODUCT SPECIFICATIONS” section of this manual.

ENGINE COOLING SYSTEM

To insure proper cooling, make sure the grass screen, cooling fins, and other external surfaces of the engine are kept clean at all times.

16

Page 16
Image 16
Husqvarna 96045002700 Transaxle Cooling, Transaxle Pump Fluid, V-Belts, Lubrication, Engine Oil Filter, Air Filter