The operator must wear protective clothing appropriate to the work he is doing. We recommend that this includes both eye and ear protection.

Any person not involved in the work should leave the working area.

Use core bits which are suitable for the work to be done.

7. Fitting and Removing the Motor

Unplug the motor from the outlet.

Always remove the core bit before fitting or removing the motor.

Engage the carriage brake. The motor is mounted on the frame by means of a support collar.

8. Electrical Connection

ELECTRICAL SAFETY:

Operate this machine only on a supply equipped with a 30 mA grounded current- limiting circuit breaker.

The Ground Fault Circuit Interrupter (GFCI) must be used correctly, including testing it regularly. For tools supplied with an integral GFCI in the cable or in the main plug, if the cable or plug has been damaged, repairs must be carried out by the manufactur- er, one of his agents or by a qualified repair workshop to avoid any risks resulting from errors.

Use single phase 2 pole plus grounded sockets for the appropriate voltage. Make sure that the main voltage is the same as that on the manufacturer’s plate. Extension cables, type HO7 RNF, should have an adequate cross section for the power: 3 x 2.5 mm2 up to 50 m or double for longer cables.

9. Mounting Methods

There are three options available for fastening the base plate of your drill stand. Fastening with threaded rod and heavy-duty anchor, expanding anchor or vacuum.

120

Page 8
Image 8
Husqvarna DS160C manuel dutilisation Fitting and Removing the Motor, Electrical Connection, Mounting Methods