Image 31

Maintenance

Restoring from service position

1Grip the front edge of the unit and loosen the lock, fold down and slide in the unit.

2Replace the cutting height stay and the belt.

3Tension the belt with the belt adjuster.

4Fit the front cover.

Checking the blades

To achieve the best mowing results it is important that the blades are undamaged and well-sharpened.

Check that the blades’ attachment screws are tight.

If the blades hit a foreign body such as a stone, they should be inspected before using them again.

IMPORTANT INFORMATION

One or more unbalanced blades , caused by damage or poor balancing after sharpening, can cause vibrations in the machine.

Replacing the blades

Put the unit in the service position, see Service position for the cutting unit.

Lock the blade with a wooden block. Loosen the blade bolt and remove the blade bolt, the washer and the blade.

Assemble the parts in the reverse order.

The blade must be mounted with the angled ends pointing up towards the cover.

Tightening torque 45-50 Nm (4.5-5 kpm/32-36 lbft).

15mm

!

WARNING! Wear gloves to protect your

hands when working with the blades.

 

IMPORTANT INFORMATION Always exercise care and use your common sense. Avoid all situations which you consider to be beyond your capability. If you still feel uncertain about operating procedures after reading these instructions, you should consult an expert before continuing. Contact an authorised service workshop.

Always use genuine parts. For more information, see the ”Technical data” section.

Removing the BioClip plug

To change a Combi unit from BioClip function to cutting unit with rear ejection, remove the BioClip plug located under the unit with three screws.

1Put the unit in the service position, see Placing in the service position.

2Remove the three screws holding the BioClip plug, and remove the plug.

3Tip: Fit three full-thread screws M8x15 mm in the screw holes to protect the threads.

4Replace the unit in normal position.

Fit the BioClip plug in the reverse order.