English – 11
ASSEMBLY
Fit the blade guard1 Slip in the blade guard guide between the stays on the
blade guard. Place the blade guard guide in the middle.
Lock the plastic heel on the handle to the upper stay on
the blade guard.
2 Make sure that the pivot arm is positioned vertically. Lift
the blade guard over the blade and hang the guard in the
blade guard holder on the saw. Exercise care so that the
runners on the blade guard are positioned in the slots on
the water block.
3 Lock the blade guard by pulling the handle out of the
guard and then down towards the saw unit so that the
latch locks the handle.
4 To remove the guard, release the latch and pull the handle
upwards and inwards to the guard. Lock the plastic heel
on the upper stay.
5 Connect the water hose from the out-coupling on the saw
motor to the in-coupling on the blade flange hub.
Connect the power unitRead through the manual supplied with the power unit before
starting to use the machine.
When the saw unit, the blade and the blade guard are
mounted, the power cable (A) and the water cooling (B)
should be connected to the power unit.
!
WARNING! Never mount or dismount the
blade or blade guard without first pulling out
the power cable running to the saw unit.
Carelessness can result in serious personal
injury or even death.
IMPORTANT! This machine is only intended for use
together with a Husqvarna PP 440 HF. All other use is
forbidden.