LUBRICATION

Checking the oil level

Check the oil level in the engine when the machine is standing level and the engine is stopped.

Remove the dipstick, wipe it clean, and then replace it.

The dipstick should be screwed into place.

Take the dipstick out again and read the oil level.

The oil level shall lie between the markings on the dipstick. If the level is approaching the ”ADD” mark, top up the oil to the ”FULL” mark on the dipstick.

Never fill above the ”FULL” mark.

The oil is filled through the hole for the dipstick.

API class SF, SG, SH, SJ or higher must be used

Syntetic oil SAE 5W-30 or 10W30 is recommended at all temperatures.

Mineral oil SAE 5W-30, 10W30 can be used between 0 °F/-18 °C and 40 °F/+5 °C. At temperature above 40 °F/+5 °C single grade SAE 30 must be used.

The engine holds 1.5 quarts gallon (1.4 liters) of oil excluding the filter; including the filter 1.6 quarts gallon (1.5 liters).

8011-500

Remove the dipstick

8009-159

The dipstick markings

English-55

Page 57