Soap and hot water are not enough to kill this bacteria. A sanitizing solution must be included with each cleaning pro- cess to eliminate this bacteria.
1.Scrub thoroughly, cleaning all surfaces, with soap and hot water.
2.Rinse with hot water, but do not flood.
3.Apply the sanitizing solution according to Hussmann’s directions.
4.Rinse thoroughly.
5.Dry completely before resuming operation.
CLEANING GLASS & MIRRORS
Only use a soft cloth and mild glass cleaner for cleaning any glass or mirrored components. Be sure to rinse and/ or dry completely.
Never use hot water on cold glass surfaces! It may shatter and cause serious injury! Allow glass
surfaces to warm first.
PLEXIGLASS & ACRYLIC CARE
Improper cleaning not only acelerates the cleaning cycle but also degrades the quality of this surface. Normal daily buffing motions can generated static cling attracting dust to the surface. Incorrect cleaning agents or cleaning cloths can cause micro scratching of the surface,causing the plastic to haze over time.
CLEANING
Hussmann recommends using a clean damp chamois, , or a paper towel marketd as dust and abrasive free with 210® Plastic Cleaner and Polish available by calling Sumner Labs at
ANTISTATIC COATINGS
The 210® has proven to be very effective in not only clean- ing and polishing the Plexiglass surface, but also providing
Maintenance
BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component
This includes (but not limited to) Fans, Heaters,
Thermostats, and Lights.
REPLACING FLUORESCENT LAMPS
Fluorescent lamps are furnished with moisture resistant lamp holders, shields and end caps.Whenever a florescent lamp is replaced, be certain to reinstall the lamp shield and end caps over the lamp.The lamps supplied are single
COPPER COILS
The copper coils used in Hussmann merchandisers may be repaired in the field. Materials are available from local refrigeration wholesalers.
Hussmann recommends using #15
TIPS & TROUBLESHOOTING
Before calling for service, check the following:
1.Check electrical power supply to the equipment for connection.
2.Check fixture loading. Overstocking case will affect its proper operation.
3.If frost is collecting on fixture and/or product, check that Humidity Control is working properly, and that no outside doors or windows are
ENCAPSULITE
SHATTERPROOF COATING - SA 10645
RU | Complies with FDA USDA |
|
R |
|
|
| & OSHA Regulations | NSF |
|
|
for replacement call:
Turn switch off then on after replacing bulb
FOR PROMPT SERVICE
When contacting the factory,
be sure to have the Case Model and Serial Number handy. This information is on a plate located on the case itself.
EVAPORATOR FANS
The evaporator fans are located at the center front of these merchandisers directly beneath the display pans.
14