PLEXIGLASS & ACRYLIC CARE

IGSS-FMSS-0301

Soap and hot water are not enough to kill this bacteria. A sanitizing solution must be included with each cleaning pro- cess to eliminate this bacteria.

1.Scrub thoroughly, cleaning all surfaces, with soap and hot water.

2.Rinse with hot water, but do not flood.

3.Apply the sanitizing solution according to Hussmann’s directions.

4.Rinse thoroughly.

5.Dry completely before resuming operation.

CLEANING GLASS & MIRRORS

Only use a soft cloth and mild glass cleaner for cleaning any glass or mirrored components. Be sure to rinse and/ or dry completely.

Never use hot water on cold glass surfaces! It may shatter and cause serious injury! Allow glass

surfaces to warm first.

PLEXIGLASS & ACRYLIC CARE

Improper cleaning not only acelerates the cleaning cycle but also degrades the quality of this surface. Normal daily buffing motions can generated static cling attracting dust to the surface. Incorrect cleaning agents or cleaning cloths can cause micro scratching of the surface,causing the plastic to haze over time.

CLEANING

Hussmann recommends using a clean damp chamois, , or a paper towel marketd as dust and abrasive free with 210® Plastic Cleaner and Polish available by calling Sumner Labs at 1-800-542-8656.Hard,rough cloths or paper tow- els will scratch the acrylic and should not be used.

ANTISTATIC COATINGS

The 210® has proven to be very effective in not only clean- ing and polishing the Plexiglass surface, but also providing anti-static and anti-fog capabilities.This product also seals pores and provides a protective coating.

Maintenance

BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component

This includes (but not limited to) Fans, Heaters,

Thermostats, and Lights.

REPLACING FLUORESCENT LAMPS

Fluorescent lamps are furnished with moisture resistant lamp holders, shields and end caps.Whenever a florescent lamp is replaced, be certain to reinstall the lamp shield and end caps over the lamp.The lamps supplied are single slim-line or bi-pin type with or without starters.

COPPER COILS

The copper coils used in Hussmann merchandisers may be repaired in the field. Materials are available from local refrigeration wholesalers.

Hussmann recommends using #15 Sil-Fos for repairs.

TIPS & TROUBLESHOOTING

Before calling for service, check the following:

1.Check electrical power supply to the equipment for connection.

2.Check fixture loading. Overstocking case will affect its proper operation.

3.If frost is collecting on fixture and/or product, check that Humidity Control is working properly, and that no outside doors or windows are open—allowing moisture to enter store.

ENCAPSULITE

SHATTERPROOF COATING - SA 10645

RU

Complies with FDA USDA

 

R

 

 

 

& OSHA Regulations

NSF

 

 

for replacement call:

1-800-395-9229

Turn switch off then on after replacing bulb

FOR PROMPT SERVICE

When contacting the factory,

be sure to have the Case Model and Serial Number handy. This information is on a plate located on the case itself.

EVAPORATOR FANS

The evaporator fans are located at the center front of these merchandisers directly beneath the display pans.

14

Page 14
Image 14
hussman IGSS-FMSS-0301 manual Plexiglass & Acrylic Care, Replacing Fluorescent Lamps, Tips & Troubleshooting