PLEXIGLASS & ACRYLIC CARE

CLEANING

Clean with plenty of nonabrasive soap (or detergent) and luke warm water, using the bare hand to feel and dislodge any caked-on dirt.A soft, grit-free cloth, sponge or chamois may be used, but only as a means of carrying the water to the plastic. Dry with a clean damp chamois or clean soft cloth such as cotton flannel. Hard, rough cloths or paper towels will scratch the acrylic and should not be used.

WAXING

If after removing dirt and grease, the acrylic can be waxed with a good grade commercial wax.This will improve the appearance of the surface by filling in most minor scratches. Wax should be applied in a thin even coat and brought to a high polish by rubbing lightly with a dry clean soft cloth, such as a cotton flannel. Excessive rubbing may cause scratching and/or buildup an electrostatic charge which attracts dust and dirt to the surface. Blotting with a clean damp cloth is recommended to remove charge.

Rev.0309

ANTISTATIC COATINGS

For acrylic used indoors, antistatic coatings successfully prevent the accumulation of an electrostatic charge for periods of several months—if the surface is not washed or wiped down with a wet cloth. Between applications of the antistatic coatings, the parts need only be dusted with a soft clean cloth to maintain a good appearance. In use, liquid antistatic coatings should be applied in a very thin even coat. If beads appear as it is applied, the coat is too thick and the excess should be removed with another cloth. Allow the coating to dry, then bring to a high gloss with a soft cloth.

 

Maintenance

ELECTRICAL PRECAUTIONS

COPPER COILS

 

The copper coils used in Hussmann merchandisers may

 

be repaired in the field. Materials are available from local

 

refrigeration wholesalers.

 

Hussmann recommends using #15 Sil-Fos for repairs.

BEFORE SERVICING – Always disconnect electrical power at the main disconnect when servicing or replacing any electrical component

This includes (but not limited to) Fans, Heaters,

Thermostats, and Lights.

REPLACING FLUORESCENT LAMPS

Fluorescent lamps are furnished with moisture resistant lamp holders, shields and end caps.Whenever a florescent lamp is replaced, be certain to reinstall the lamp shield and end caps over the lamp.The lamps supplied are single slim-line or bi-pin type with or without starters.

EVAPORATOR FANS

The evaporator fans are located at the center front of these merchandisers directly beneath the display pans. Should fans or blades need servicing, always replace fan blades with the raised embossed side of the blade TOWARD THE MOTOR.

TIPS & TROUBLESHOOTING

Before calling for service, check the following:

1.Check electrical power supply to the equipment for connection.

2.Check fixture loading.Overstocking case will affect its proper operation.

3.If frost is collecting on fixture and/or product, check that Humidity Control is working properly,and that no outside doors or windows are open—allowing moisture to enter store.

FOR PROMPT SERVICE

When contacting the factory,

be sure to have the Case Model and Serial Number handy. This information is on a plate located on the case itself.