T-STAT LOCATION

The T-stats are located within the electrical raceway.The raceway location is dependent on the style of the front panel and whether the case is going to be pushed up against a wall. (See diagram.)

In all cases, the T-stat is located on the same side of the case. If you are looking at the case from the front, it is the right- hand side. If you are looking at the case from the back, it is the left-hand side.

Rev.0309

START-UP

SELF CONTAINED

On self contained cases the unit is completely charged and tested to the porper temperature.Siwtch on the com- pressor. Set the timeclock to the proper time of day by turning the dial in the direction of the arrow until the pointer and current time of day align.

REMOTE

After proper testing, evacuation and charging, set the coil or evaporation temperature to 15°F by the method engineered into your system.A thermostat is located on the top of thje case for temperature control. Set the thermostat to cycle in and out as per the Case Specification section of the guide. Set the timeclock to

Electrical

WIRING COLOR CODE

GREEN

GROUND

PURPLE

ANTI-SWEAT

ORANGE

LIGHTS

YELLOW

RECEPTACLE

RED / BLACK

T-STAT /SOLENOID230V

BLACK / WHITE

T-STAT / SOLENOID 115V

BROWN

FAN MOTORS

 

 

CASE MUST BE GROUNDED

NOTE: Refer to label affixed to case to determine the actual configuration as checked in the “TYPE INSTALLED” boxes.

ELECTRICAL CIRCUIT IDENTIFICATION

Standard lighting for all models will be full length fluorescent lamps located within the case at the top.

The switch controlling the lights, the plug provided for digital scale, and the thermometer are located at the rear of the case mullion.

The receptacle that is provided on the exterior back of these models is intended for computerized scales with a five amp maximum load, not for large motors or other high wattage appliances. It should be wired to a dedicated circuit.

BEFORE SERVICING

ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT.

This includes (but not limited to) Fans, Heat-

ers, Thermostats, and Lights.

FIELD WIRING & SERIAL PLATE AMPERAGE

Field Wiring must be sized for component amperes printed on the serial plate.Actual ampere draw may be less than specified. Field wiring from the refrigeration control panel to the merchandisers is required for refrigeration thermostats. Most component amperes are listed in the “Case Specs” section, but always check the serial plate.

BALLAST LOCATION

Ballasts are located within the access panel that runs the length of the rear of the case.

Finishing Touches

If more than one RED is being installed next to each other, the factory fitted continuous fascia may need to be in- stalled.All fasciae rest on the top of their cases.The self- contained fascia has a hook that needs to be slid through a gusset on the side of the case.

7