WIRING COLOR CODE

Rev. 0904

Electrical

WIRING COLOR CODE

STANDARD CASE WIRE COLOR CODE

CODIGO DE COLORES DE LOS ALAMBRES PARA LAS VITRINAS ESTANDAR

CODE COULEUR POUR FILS DE BOITIER NORMALISE

C o l o r D e s c r i p t i o n

D e s c r i p c i o n

D e s c r i p c i o n

 

 

 

GROUND

TIERRA MASA

MASSE

 

 

 

ANTI - SWEAT

ANTICONDENSCION

ANTI - SUINTEMENT

 

 

 

 

 

 

 

 

LIGHTS

LUCES

ECLAIRAGE

 

 

 

 

 

 

 

 

RECEPTACLES

ENCHUFER

RECEPTACLE

 

 

 

 

 

 

 

 

T- STAT/SOLENOID 230 V

THERMOSTATO / SOLENOID (230 VAC)

SOUPAPE A SOLENOID (230 V)

 

 

 

 

 

 

 

 

T- STAT/SOLENOID 115 V

THERMOSTATO / SOLENOID (115 VAC)

SOUPAPE A SOLENOID (115 V)

 

 

 

FAN MOTORS

VENTILADORES

VENTILATEUR

 

 

 

 

 

 

 

430 - 01 - 0338 r9908

CASE MUST BE GROUNDED

NOTE: Refer to label illustrated above that is affixed to case to determine the actual configuration as checked in the “TYPE INSTALLED” boxes.

ELECTRICAL CIRCUIT IDENTIFICATION

Standard lighting for all models will be full length fluores- cent lamps located within the case at the top.

The switch controlling the lights, the plug provided for digital scale, and the thermometer are located at the rear of the case mullion.

less than specified. Field wiring from the refrigeration control panel to the merchandisers is required for re- frigeration thermostats. Most component amperes are listed in the “Case Specs” section, but always check the serial plate.

BALLAST LOCATION

Ballasts are located within the access panel that runs the length of the rear of the case. Refer to diagram on page 6.

WIRING & SERIAL PLATE AMPERAGE

Field Wiring must be sized for component amperes stamped on the serial plate. Actual ampere draw may be less than specified. Field wiring from the refrigeration con trol panel to the merchandisers is required for refrigera- tion thermostats. Most component amperes are listed in the "Case Specs" section, but always check the serial plate.

ASHRAE COLOR CODE

NOTE: All other manufacturers have no standard sensor codes.

ELECTRICAL SERVICE RECEPTACLES (WHEN APPLICABLE)

The receptacle that is provided on the exterior back of these models is intended for computerized scales with a fifteen amp maximum load, not for large motors or other high wattage appliances. It should be wired to a dedicated circuit.

BEFORE SERVICING

ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT.

This includes (but not limited to) Fans, Heat-

ers, Thermostats, and Lights.

FIELD WIRING & SERIAL PLATE AMPERAGE

Field Wiring must be sized for component amperes printed on the serial plate.Actual ampere draw may be

Case Control Systems

SENSOR COLOR

 

 

 

 

 

Manufacturer ® >

 

EIL

CP

 

 

 

 

Location

 

 

 

 

 

 

 

Coil Inlet

Color

Blue

Blue

 

 

 

 

 

Part#

225-01-1755

225-01-3255

 

 

 

 

Coil Outlet

Color

Red

Red

 

 

 

 

 

Part#

225-01-1757

225-01-3123

 

 

 

 

Discharge Air

Color

Green

Green

 

 

 

 

 

Part#

225-01-1756

225-01-3260

 

 

 

 

Return Air

Color

Purple

Green

 

 

 

 

 

Part#

225-01-1758

225-01-3260

 

 

 

 

Defrost Term.

Color

White

Orange

 

 

 

 

 

Part#

225-01-0650

225-01-3254

 

 

 

 

Liquid Line

Color

White

Blue

 

 

 

 

 

Part#

225-01-0650

225-01-3255

 

 

 

 

13