CABLE CONNECTION 18/24 Btuh (Single Zone Only)
4.Fix the connecting wire between units, with wiring fixture.
5.Attach the wiring cover.
ELECTRICAL SPECIFICATIONS AND SYSTEM PERFORMANCE
Single Zone | Cooling Capacity | SEER | Heating Capacity | HSPF | Volts/HZ/Phase | Total | MCA | Max. | |
System | Nominal (1) | Sensible | (Btuh) (2) | Amps | Fuse | ||||
HCW9000 | 9,500 | 7,030 | 10.9 | - | - | 208/230/60/1 | 5.0 | 6.1 | 15 |
HCW12000 | 12,000 | 8,760 | 10.6 | - | - | 208/230/60/1 | 6.2 | 7.6 | 15 |
HHW12000 | 12,000 | 8,760 | 10.4 | 12,500 | 7.2 | 208/230/60/1 | 6.2 | 7.6 | 15 |
HCW18000 | 20,000 | 14,200 | 10.7 | - | - | 208/230/60/1 | 10.2 | 12.5 | 20 |
HHW18000 | 20,000 | 14,200 | 10.3 | 20,000 | 6.9 | 208/230/60/1 | 10.2 | 12.5 | 20 |
HCW24000 | 24,000 | 16,800 | 10.3 | - | - | 208/230/60/1 | 12.1 | 14.8 | 25 |
HHW24000 | 24,000 | 16,800 | 10.0 | 24,000 | 6.8 | 208/230/60/1 | 12.0 | 14.8 | 25 |
(1)Indoor 80/67º F, Outdoor 95º F
(2)Indoor 70/58º F, Outdoor 47º F
Cooling Capacity |
| Heating |
|
| Cond Fan Mtr | Compressor | Indoor Fans | Total |
| HACR | Min | |||||
(Btuh) | SEER | Capacity | HSPF | Volts/HZ/Phase | Circuits 1 & 2 | MCA | ||||||||||
System | Nominal (5) | Sensible |
| (Btuh) (6) |
|
| AMPS | HP | RLA | LRA | AMPS | HP | Amps |
| BRKR | Volt |
HMCW18000 (1) | 18,000 | 12,600 | 10.9 | - | - | 208/230/60/1 | 0.72 | 0.2 | 4.45 | 26 | 0.22 | 0.06 | 10.1 | 11.1 | 15 | 197 |
HMHW18000 (2) | 17,400 | 11,700 | 10.0 | 17,700 | 6.8 | 208/230/60/1 | 0.72 | 0.2 | 4.45 | 26 | 0.22 | 0.06 | 10.1 | 11.1 | 15 | 197 |
HMCW24000 (3) | 24,000 | 15,500 | 10.6 | - | - | 208/230/60/1 | 0.72 | 0.2 | 5.85 | 29 | 0.22 | 0.06 | 12.9 | 13.4 | 20 | 197 |
HMHW24000 (4) | 21,000 | 14,100 | 10.0 | 21,250 | 6.8 | 208/230/60/1 | 0.72 | 0.2 | 5.85 | 29 | 0.22 | 0.06 | 12.9 | 13.4 | 20 | 197 |
(1)HMCW18000 consists of tw o HACM09DB (9,000 Btuh) air handlers and one HCCM09DB condenser.
(2)HMHW18000 consists of tw o HAHM09DB (9,000 Btuh) air handlers and one HCHM09DB condenser.
(3)HMCW24000 consists of tw o HACM12DB (12,000 Btuh) air handlers and one HCCM12DB condenser.
(4)HMHW24000 consists of tw o HAHM12DB (12,000 Btuh) air handlers and one HCHM12DB condenser.
(5) Indoor 80/67º F, Outdoor 95º F | (6) Indoor 70/58º F, Outdoor 47º F |
COMPLETION OF INTERCONNECTING TUBING
•Insert the wall cap into the wall, and fill the gap with sealant to prevent rain or wind.
•When using the pipe cover, fill the gap in the wall through hole in the inside.
ECR International | 16 | Hyundai Ductless Split System |