I.C.T.C. Holdings Corporation Pressure Washer Important Operation / Maintenance Precautions

Models: PW2000-SC Pressure Washer PW2700-SC

1 20
Download 20 pages 25.51 Kb
Page 4
Image 4
IMPORTANT OPERATION / MAINTENANCE PRECAUTIONS

IMPORTANT OPERATION / MAINTENANCE PRECAUTIONS

!Change oil in pump after the first 50 hours, then every 500 hours.

Use SAE30 Non-Detergent Motor oil.

!Change engine oil as specified by the Honda. See Honda owners manual.

"Do Not run washer longer than 3 minutes with gun closed, as this can result in damage to the seals. Heat generated by the re-circulating water can damage seals.

"Avoid freezing pump. Drain unit prior to storage, or run an antifreeze solution through pump. Ensure the pump and hoses are completely bleed of all liquid.

START-UP AND OPERATION INTRODUCTION

1.Verify that the vented YELLOW dip stick is installed in pressure washer pump. Remove the RED shipping plug ( if present ) from top of the pump and replace it with the YELLOW oil level dipstick provided. Fig. 1

2.Before first use, check engine and pump oil levels.

Note: For shipping purposes, engine oil has not been added.

Before each use, check engine oil level by unscrewing the oil dipstick. Add motor oil (consult Honda manual for correct grade) as required to bring to proper level, approximately mid-way on dipstick.

3.Check water supply volume. To operate correctly, the unit requires a water supply 25% greater than the units output. ( i.e. PW2700SC = 3 GPM, PW2000SC = 3.75 GPM of water flow).

To test water supply output;

a)Turn water flow to full maximum output.

b)Place a 5 gallon pail or container under water flow for exactly 1 minute ( 60 seconds).

c)Measure contents to determine water flow.

4.Connect a standard garden hose to the water inlet or bottom connection on the pump head ( Female hose connector ). Fig. 2.

YellowUse SAE30 Non-Detergent Motor oil.

Red

Fig. 1

Fig. 2

Pressure

Control START-UP AND OPERATION INTRODUCTION

5.Connect the high pressure hose to the water “Outlet” or upper connection on the pump head.

( Male quick connect nipple). Fig. 2.

6.Turn the unloader knob on top of the pump head counter- clockwise to reduce the pressure prior to starting the machine.

7.Select the desired tip for the job. Insert tip into wand

Outlet

Injector

Inlet

H.E.R.O. Industries

Page 4

Pressure Washer Owners Manual

Page 4
Image 4
I.C.T.C. Holdings Corporation Pressure Washer Important Operation / Maintenance Precautions, H.E.R.O. Industries