Diagnostic
Error
Code
FRU/Action
035-196-XXX
RAID
interface
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
035-197-XXX
RAID
interface
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
035-198-XXX
RAID
interface
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
the
″Undetermined
problems″
section
035-199-XXX
RAID
interface
test
failed,
cause
unknown
1.
Go
to
the
″Undetermined
problems″
section
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
071-000-XXX
Audio
port
Interface
Test
Passed
1.
No
action
071-00X-XXX
071-01X-XXX
071-02X-XXX
Audio
port
error
1.
Run
Setup
2.
Flash
the
system
3.
System
board
071-03X-XXX
Audio
port
failure
1.
Speakers
2.
Microphone
3.
Audio
card,
if
installed
4.
System
board
071-04X-XXX
Audio
port
failure
1.
Run
Setup
2.
Audio
card,
if
installed
3.
System
board
071-195-XXX
Audio
port
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
071-196-XXX
Audio
port
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
071-197-XXX
Audio
port
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
071-198-XXX
Audio
port
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
the
″Undetermined
problems″
section
Chapter
7.
Symptom-to-FRU
index
61