POST
Error
Code
FRU/Action
185XXXX
1.
DBCS
Japanese
Display
Adapter/A
2.
System
Board
3.
Riser
card
20001
to
20003
1.
Image
Adapter/A
Image-I
Adapter/A
2.
Memory
Module
DRAM,
VRAM
20004
1.
Memory
Module
DRAM,
VRAM
2.
Image
Adapter/A
Image-I
Adapter/A
20005
to
20010
1.
Image
Adapter/A
Image-I
Adapter/A
2.
Memory
Module
DRAM,
VRAM
200XX
Not
listed
above
1.
Image
Adapter/A
2.
Image-I
Adapter/A
3.
Memory
Module
DRAM,
VRAM
4.
System
Board
5.
Riser
card
20101
to
20103
1.
Printer/Scanner
Option
2.
Image
Adapter/A
3.
Memory
Module
DRAM,
VRAM
20104
1.
Memory
Module
DRAM,
VRAM
2.
Printer/Scanner
Option
3.
Image
Adapter/A
20105
to
20110
1.
Printer/Scanner
Option
2.
Image
Adapter/A
3.
Memory
Module
DRAM,
VRAM
Image
Adapter/A
Memory
Test
failure
indicated
by
graphic
of
adapter
1.
Replace
memory
module
(shown
in
graphic)
206XX
1.
SCSI-2
Adapter
2.
Any
SCSI
Device
3.
System
Board
4.
Riser
card
208XX
Verify
there
are
no
duplicate
SCSI
ID
settings
on
the
same
bus.
1.
Any
SCSI
Device
210XXXX
Internal
bus,
size
unknown
210XXX1
External
bus,
size
unknown
1.
SCSI
Hard
Disk
Drive
2.
SCSI
Adapter
or
System
Board
3.
SCSI
Cable
4.
SCSI
ID
Switch
(on
some
models)
Tape
Drive
amber
LED
remains
on
1.
Tape
Drive
2.
SCSI
Cable
(internal)
3.
SCSI
Adapter
or
System
Board
82
Hardware
Maintenance
Manual
Types
2292,
2273,
6043,
6343,
6349,
6350,
6790,
6791,
6792,
6793,
6794,
6795,
6823,
6825