Peripheral

Device

Related

Symptoms

 

Symptom/Error

 

 

FRU/Action

 

 

 

 

 

 

 

External

display

does

not 1. See

“External Display

work correctly.

 

Self-Test” in the

 

 

 

“Common

Devices

 

 

 

Checkout”

section.

 

 

 

 

Printer

problems.

1. Run

Printer Self-test .

2.System Board

3.Parallel Port Device

4.Cable

Serial or parallel port device1.Device

problems.

2.

Device Cable

 

3.

System Board

Other Symptoms

Symptom/Error

 

 

 

FRU/Action

 

 

 

 

 

 

 

 

PCMCIA

slot

pin

is

 

1.System Board

 

damaged.

 

 

 

 

 

 

 

 

 

 

 

 

Note:

If

you

cannot

find a symptom or error in this list

 

and the problem remains, see “Undetermined

 

Problems.”

 

 

 

Intermittent Problems

Intermittent system hang problems can be caused by a variety of reasons that have nothing to do with a hardwar defect such as: cosmic radiation, electrostatic discharge, software errors. FRUs replacement should only be considered when a recurring problems exists.

When analyzing the intermittent problem, do the following:

1.

Run

the

advanced diagnostic test for the system

 

board

in

loop mode at least 10 times.

2.

If

no

 

error is detected,not replacedoany FRUs.

3.

If

any

error is detected, replace the FRU shown by

 

the

FRU

code. Rerun the test to verify that no more

 

errors

exist.

Undetermined Problems

You are here because the diagnostic tests did not ident which adapter or device failed, installed devices are incorrect, a short circuit is suspected, or the system is inoperative. Follow the procedures below to isolate the failing FRU (do not isolate non-defective FRUs).

Verify that all attached devices are supported by the computer.

Verify that the power supply being used at the time of failure is operating correctly. (See “Power Systems Checkout” on page 29.)

1. Power-off the computer.

42 IBM Mobile Systems HMM