Table 10 outlines the components used in Figure 8.

Table 10. The components used in Figure 8

Diagram

 

Part number/

 

Description

 

Quantity

 

 

 

Reference

 

machine type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0563-012

 

IBM Ethernet Switch B24X

 

1

 

 

 

 

 

 

 

 

 

 

 

IBM Ethernet Switch B16M

 

 

 

 

 

 

z On B16M, use FC1711 (4-port 10 GbE XFP

 

 

 

 

4003-M16

 

module) and FC2110 (10GBASE-SR XFP).

 

1

 

 

 

 

z On B24X, use 69Y0389 (10GBASE-SR SFP+).

 

 

 

 

 

 

z Connect over multi-mode fiber.

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco Catalyst 6509-E

 

 

 

 

 

 

z On 6509, use 8-port 10 GbE Fiber module with

 

 

 

 

N/A

 

X2-10GB-SR (10GBASE-SR X2 module).

 

1

 

 

 

z Connect over multi-mode fiber. (Note: The X2

 

 

 

 

 

 

 

 

 

 

 

module has a SC connector, whereas the SFP+

 

 

 

 

 

 

has a LC connector.)

 

 

 

 

 

 

 

 

 

 

 

 

 

IBM Ethernet Switch B48Y (Data Center model)

 

 

 

 

 

 

z On B48Y, use 81Y1455 (4-port 10 GbE SFP+

 

 

 

 

 

 

module).

 

 

 

 

 

 

z Use a single Direct Attach cable (TwinAx) to

 

 

 

 

0563-HCF

 

connect to B24X, available in 1, 3, or 5 meters if

 

1

 

 

 

 

length permits.

 

 

 

 

 

 

z Otherwise, on B24X use 69Y0389

 

 

 

 

 

 

(10GBASE-SR SFP+) and connect over

 

 

 

 

 

 

multi-mode fiber.

 

 

 

 

 

 

 

 

 

 

 

 

 

Cisco Catalyst Nexus 4948-10GE

 

 

 

 

 

 

z On the Catalyst use the 10GBASE-SR X2

 

 

 

 

N/A

 

module.

 

1

 

 

 

 

z On B24X, use 69Y0389 (10GBASE-SR SFP+).

 

 

 

 

 

 

z Connect over multi-mode fiber

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supplies and fans

The IBM Ethernet Switch B24X comes with one 300 W AC power supply and supports a second power supply for 1+1 redundancy. The power supplies are hot-swappable, auto-sensing, auto-switching, and load sharing, with a universal input (90 VAC to 264 VAC). The power supply has an IEC-C14 inlet that connects to a C13 power connector. Power cords are not included with the switch and must be provided separately.

The IBM Ethernet Switch B24X also comes with a single fan tray consisting of three variable-speed fans. If one fan within the fan tray fails it does not affect the operation of the other fans in the unit. The fan tray is hot-swappable, increasing device availability and serviceability.

Figure 9. IBM Ethernet Switch B24X rear view (fans and power supply)

IBM Ethernet Switch B24X

18

Page 18
Image 18
IBM B24X manual Power supplies and fans, Part number Description Quantity