8
2

INSTALLATION AND CONNECTIONS

Using 2 Icom exciters (transceivers) The following connections also apply to trans-

ceivers having multiple antenna connectors for

specied bands (e.g. IC-726, IC-729, etc.)

IC-PW1

IC-756

Ground
Coaxial cable (supplied)
OPK-5
(optional)
ACC cable (supplied)
Remote control cable (supplied)
To an
antenna OPC-599 (optional)
EXCITER
1 1&2
ANT
ACC-1
ACC-2
ANT1
ANT1 or 2
ACC REMOTE
REMOTE
REMOTEACC(2)
REMOTE
INPUT1
INPUT2
GND
GND
GND

IC-706 series

OPK-5 (optional)
OPK-5 (optional)
Be sure to connect the cable to the 7-pin ACC(2) jack.
AC outlet
(Non-Europe versions: 100120/220240 V
Europe version : 230 V)
Using a non-Icom exciter (transceiver)

Set the [EXCITER] switch to [1] when 1 exciter is con-

nected; set to [1&2] when 2 exciters are connected.

NOTE: The specications for the SEND relay are

5 V DC 0.1 A. If this level is exceeded, a large ex-

ternal relay must be used.

IC-PW1 Ground
Coaxial cable
(supplied)
To an
antenna
ANT

Non-Icom exciter

INPUT1
RCA plug ALC
ALC1
SEND1 SEND
SEND
Relay
DC power
GND GND
ALCDC OUT SEND
RF OUT
EXCITER
1 1&2
AC outlet
(Non-Europe versions: 100120/220240 V
Europe version : 230 V)