14
3
OPERATION
■Programming the CI-V address (continued)
DSetting the IC-PW1/EURO’s address
It is not necessary to change the IC-PW1/EURO’s
default CI-V address of 54H. However, if desired, the
address can be changed using the internal address
switch illustrated below.
It is not necessary to change the IC-PW1/EURO’s
default CI-V address (default S3=5, S4=4). However,
in the case when you will connect two (2) IC-
PW1/EUROs like as above left1, please set a differ-
ent address number using the internal address switch
as illustrated as above right.
NOTE: Turn the power OFF when you are going to
change the address setting, then programming the
CI-V address again.
ïOther NOTE:
•IC-781;
NEVER TURN THE POWER OFF of the IC-781 dur-
ing the operation when you are using the IC-781 as
one of the exciters, otherwise the CI-V control may
be interrupted.
•Baud rate;
Higher baud rate (e.g. 9600 bps) gives quick opera-
tion. When you select an extra Low baud rate (e.g.
300 bps), then the IC-PW1/EURO needs max. 15
sec. to start the operation.
•“AUTO” baud rate;
When you want to use “AUTO” baud rate, turn the
non-“AUTO” baud rate exciter ON first, then turn the
“AUTO” baud rate exciter ON.
➥Push [POWER] to turn the linear amplifier ON
then turn the exciter’s power ON.
REMOTE
Icom
exciter
IC-PW1
IC-PW1
Icom
exciter
Address switch
‘Initial settings for CI-V remote control operation
Before setting the remote control operation, refer to
the following operating procedure.
ïïWhen using one (1) Icom exciter with one (1)
ANT line;
qTurn OFF both of the IC-PW1/EURO and exciter.
wSet [EXCITER] to [1] position.
eWhile pushing and holding the [INPUT] switch on
the IC-PW1/EURO controller, turn the exciter’s
power ON.
•LED [INPUT z] over the [INPUT] switch blinks.
rRotate the exciter’s dial until the LED [INPUT z]
lights continuously.
tTurn the exciter’s power OFF to complete the set-
ting.
ïïWhen using two (2) Icom exciters;
qTurn OFF both of the IC-PW1/EURO and exciters.
wSet [EXCITER] to [1&2] position.
eSet the exciter’s CI-V baud rate if required.
•
When selecting the different baud rate for each exciter,
“CI-V data” setting may fail depending on the exciter.
In such case, use the same baud rate for each exciter.
Each exciter’s frequencies may be synchronised.
•When connecting the “AUTO” baud rate exciter and
“Non-AUTO” baud rate exciter, the exciters’ frequen-
cies may not synchronize in some cases.
rWhile pushing and holding the [INPUT] switch on
the IC-PW1/EURO controller, turn the 1st exciter’s
power ON.
•LED [INPUT z] blinks.
☞
Continue to the next page
EXCITER
1 1&2
ANT
ACC-1
ANT1
ACC(2)
REMOTE
REMOTE
REMOTE
INPUT1
INPUT2
GND
GND
IC-PW1/EURO
ANT1 or 2
ACC (13 pins)
REMOTE
Optional ACC cable (included in OPK-5)
Optional remote control cable (included in OPK-5)
ACC (supplied)
GND
GND
ACC-2
OPC-599 (optional)
IC-PW1/EURO
ACC cable (supplied)
ANT ACC-1
ANT1
REMOTE
REMOTE
INPUT1
GND
GND
IC-706
ACC
OPC-599 (optional)
EXCITER
1 1&2