Battery Replacement
1)Remove the screw at the back of the Tone Generator or the Amplified Probe with a #1 Phillips- head screwdriver and remove battery door.
2)Remove old cell batteries, rapping case against the palm of the hand will dislodge batteries.
3)Install 4 new LR44 cells being careful to orient plus end of battery with plus symbol on case.
4)Replace battery door and reinsert the screw. Do not over tighten.
Product specification |
|
Power Requirements: | 4 x LR44 button cells (6 volts) |
Battery life: | Generator: 100hrs, Amplified probe: 12hrs |
Externally applied |
|
voltage w/o damage: | 250 volts peak DC or 175 volts RMS AC |
Tone frequencies | 995Hz and 845Hz alternating tones |
Tone voltage: | 12 volts |
Tone power: | 8dbm into 600 ohms, new battery |
Warranty
IDEAL guarantees to the
Shipping
1.Before returning any product to IDEAL, you must first request a Returned Materials Authorization (RMA) number by contacting our Customer Service Dept. at
No shipments will be accepted without this number, which must be clearly marked on the shipping label.
2.Ship the equipment with a copy of the sales receipt, if available.
3.Attach a description of the operational problem.
4.Include a contact name, address, phone number, and
5.Pack securely to prevent damage during shipping.
6.Ship prepaid to: IDEAL INDUSTRIES, INC.; Becker Place; Sycamore, IL 60178
Product Registration
Please visit www.idealindustries.com
IDEAL INDUSTRIES, INC. Sycamore, IL 60178, U.S.A.
ND